Server Menu (continued)
Feature
Temperature Sensor
POST Error Pause
Platform Event Filtering

System Management Submenu

Feature
Board Part Number
Board Serial Number
System Part Number
System Serial Number
Chassis Part Number
Chassis Serial Number
BIOS Version
BMC Revision
HSBP Revision

Console Redirection Submenu

Feature
Serial Console Redirection
Serial Port
Baud Rate
Flow Control
cc2300 Carrier Grade Server Product Guide
Option
Description
[Disabled]
If enabled, the system will not boot if the ambient
Enabled
temperature is outside the range specified in
the SDR.
[Enabled]
If enabled, the system will wait for user intervention
Disabled
on critical POST errors. If disabled, the system will
boot with no intervention, if possible.
[Enabled]
Enable/Disable trigger for system sensor events
Disabled
inside the BMC.
Option
Description
[A46044-405]
Field is informational only.
[KKC212600176]
Field is informational only.
Field is informational only.
Field is informational only.
Field is informational only.
Field is informational only.
Field is informational only.
Field is informational only.
[ N/A ]
Field is informational only.
Option
Description
[Disabled]
Enabled
[COM1 3F8 IRQ4]
COM2 2F8 IRQ3
COM3 3E8 IRQ4
9600
Selects the serial port's baud rate
[19.2K]
38.4K
115.2K
No Flow Control
[CTS/RTS]
Hardware control
XON / XOFF
Software control
CTS / RTS + CD
Hardware + Carrier Detect (for Modem use)