16.3.2 Shield Termination Technique – Method A.1 (Standard)
NOTE
For the following steps please refer to the drawings showing the installation of a
Jackscrew Backshell.
1. The appropriate number of Jackscrew Backshells will be included in the particular LRU connector
kit.
Table 16-6 Shielded Cable Preparations for Garmin Connectors
Number of
Backhell
Pins Std/
Size
HD
1
9/15
2
15/26
3
25/44
4
37/62
5
50/78
2. At one end of a shielded cable (item 2) measure a distance between "Window Min" to "Window
Max" (Table 16-6) and cut a window (max size 0.35") in the jacket to expose the shield (Figure
16-6). Use caution when cutting the jacket to avoid damaging the individual braids of the shield.
When dealing with a densely populated connector with many cables, it may prove beneficial to
stagger the windows throughout the "Window Min" to "Window Max" range. If staggering is not
needed the "Ideal Window" length is recommended.
Suggested tools to accomplish the window cut:
Coaxial Cable Stripper
Thermal Stripper
Sharp Razor Blade
G3X Installation Manual - Connector Installation Instructions
Page 16-8
Figure 16-6 Method A.1 for Shield Termination
Float Min
Float Max
(inches)
(inches)
1.25
2.25
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
Window
Ideal Float
Min
(inches)
(inches)
1.75
2.75
2.0
3.0
2.0
3.0
2.0
3.0
2.0
3.0
Window
Ideal
Max
Window
(inches)
(inches)
5.25
4.25
5.5
4.5
5.5
4.5
5.5
4.5
5.5
4.5