16 CONNECTOR INSTALLATION INSTRUCTIONS

16.1 Thermocouple Installation into a Backshell

Table 16-1 lists parts needed to install a Thermocouple. Parts for this installation are included in the
Thermocouple Kit (011-00981-00), which is included in the G3X w/GSU 73Installation Kit
(K10-00017-00).
Figure Ref
1
3" Thermocouple, K type
2
3
NOTE
For the following steps please refer to indicated item numbers in Figure 16-1 and
Figure
16-2.
1. Strip back approximately 0.17 inches of insulation from both the positive and negative
thermocouple leads (item 1) and crimp a pin (item 2) to each lead. It is the responsibility of the
installer to determine the proper length of insulation to be removed. Wire must be visible in the
inspection hole after crimping and the insulation must be 1/64 – 1/32 inches from the end of the
contact as shown in Figure 16-1.
2. Insert newly crimped pins and wires (items 1 & 2) into the appropriate connector housing (item 4)
location as specified by the installation specific wiring diagram.
3. Place thermocouple (item 1) body onto backshell (item 5) boss. Upon placing the thermocouple
(item 1) body, orient it such that the wires exit downward.
4. Attach thermocouple (item 1) tightly to backshell (item 5) using screw (item 3).
5. Attach cover (item 6) to backshell (item 5) using screws (item 7).
190-01115-01
Rev. L
Table 16-1 Thermocouple Kit GPN 011-00981-00
Description
Pins #22 AWG
Screw
Figure 16-1 Insulation/Contact Clearance