14.3.1.1 Lycoming and Continental Engine Sensor Installation

General Installation Guidance – To maintain measurement accuracy, thermocouple (TC) wire must be
connected directly to the inputs of the GEA 24/GSU 73. If the supplied sensor wires are not long enough
to connect directly to the GEA 24/GSU 73, then Type K TC extension wire must be used. To minimize
risk of breakage, it is recommended that a high-quality stranded (as opposed to solid) thermocouple wire
be used. One such example of appropriate wire is TT-K-22S Type K thermocouple wire from Omega
Engineering.
When using Alcor Type K probes, refer to Alcor CHT Installation Instructions (P/N 59167) for complete
installation details. Engine manufacturer's guidance should always be consulted for proper location of
CHT probes. A finger sized loop should be provided to allow sufficient strain relief of the probe assembly,
and care should be taken to ensure that no chafing of the wires occurs.
Figure 14-2 CHT Probe Package
Figure 14-3 CHT Probe Well