APPENDIX F LYCOMING/CONTINENTAL SENSOR WIRING EXAMPLES
NOTES
7.
GROUNDING METHODS FOR ELECTRONIC TACH SIGNALS MAY VARY BASED ON THE MANUFACTURER.
IGNITION MANUFACTURER DOCUMENTATION FOR SPECIFIC GROUNDING GUIDANCE. THE CAP FUEL 1/ RPM 2 INPUT (GSU 73) OR
RPM 2 (GEA 24) INPUT CAN BE OPTIONALLY USED ON AIRCRAFT WITH DUAL ELECTRONIC IGNITION.
9.
PINOUT SHOWN FOR PACKARD CONNECTOR SUPPLIED WITH KAVLICO PRESSURE TRANSDUCERS.
FOR REFERENCE ONLY, ALWAYS CONFIRM CORRECT SENSOR CONNECTIONS USING SENSOR MANUFACTURER DOCUMENTATION
BEFORE CONNECTING WIRES.
Figure F-1.1 Notes for Lycoming/Continental Sensor Drawings (for all Appdx F drawings)
190-01115-01
Rev. L
G3X Installation Manual - Lycoming/Continental Sensor Wiring Examples
CONSULT THE ELECTRONIC
WIRE COLORS ARE SHOWN
Page F-1