24.4.2 Shield Termination Technique – Method A.1 (Standard)
NOTE
For the following steps please refer to
1. The appropriate number of Jackscrew Backshells will be included in the particular LRU connector
kit.
Table 24-7 Shielded Cable Preparations for Garmin Connectors
Number
Backshell-
of Pins
Size
Std/HD
1
9/15
2
15/26
3
25/44
4
37/62
5
50/78
2. At one end of a shielded cable (item 2,
"Window Max" (Table 24-7) and cut a window (max size 0.35") in the jacket to expose the shield
(item 4, Figure 24-7). Use caution when cutting the jacket to avoid damaging the individual braids
of the shield. When dealing with a densely populated connector with many cables, it may prove
beneficial to stagger the windows throughout the "Window Min" to "Window Max" range. If
staggering is not needed the "Ideal Window" length is recommended.
Suggested tools to accomplish the window cut:
Coaxial Cable Stripper
Thermal Stripper
Sharp Razor Blade
190-01115-01
Rev. AC
Figure 24-6
Figure 24-7 Method A.1 for Shield Termination
Float Min
Float Max
(inches)
(inches)
1.25
2.25
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
Figure
G3X/G3X Touch Installation Manual - Connector Installation Instructions
and Figure 24-7.
Window
Ideal Float
Min
(inches)
(inches)
1.75
2.75
2.0
3.0
2.0
3.0
2.0
3.0
2.0
3.0
24-6) measure a distance between "Window Min" to
Window
Ideal
Max
Window
(inches)
(inches)
5.25
4.25
5.5
4.5
5.5
4.5
5.5
4.5
5.5
4.5
Page 24-9