c.
Continue to push until the J68 connector (A) appears in the opening.
5.
Route the MPF tray assembly sensor cable through the same openings.
6.
Connect J68 to the engine board.
7.
Connect the MPF tray assembly sensor cable to the engine board at J70.
8.
Install the new cable tie (B) on the cable bundle and trim the excess cable tie flush. Replace other cable
ties you removed in earlier steps.
B
5060-00x
4-77
Repair information