Chapter 8
Troubleshooting the CTS 1300
Figure 8-21
Step 2
Click the Right radio button in the Cisco TelePresence Administration interface.
Step 3
Click Show Camera Target.
Step 4
Focus the right camera by completing the following steps:
a.
Loosen the focus ring thumbscrew on the lens of the center camera.
Rotate the focus ring until the black plus sign (+) on the target is clearly in focus.
b.
Note
Adjust the camera mounting plate to center the red plus sign (+) on the display inside the black plus sign 
Step 5
(+) on the target.
Figure 8-19
Use the top two screws for left and right adjustment.
The lower screw for up and down adjustment.
The screws in the middle for adjustments on the horizontal plane (rotational).
Adjust the camera zoom by completing the following steps:
Step 6
Loosen the thumbscrew for the zoom ring on the camera lens.
a.
Note
Adjust the camera zoom so that the black curved line on the right of the target touches the right edge
b.
of the display screen, as shown in
After you adjust the zoom, make any required adjustments to the focus with the focus ring.
c.
OL-21845-01
Positioning the Right Target
Display
Alignment
The camera lens has two adjustment rings, one for focus and one for zoom, as shown in
Figure
8-17. The focus ring is the one that is nearest to the wall.
shows the screws that you use to adjust the camera. Use a 2.5 mm Allen wrench.
The zoom ring is labeled "W-T."
Right participant
sitting position
marker
camera target
Figure
8-22.
Cisco TelePresence System Administration Guide
Managing CTS 1300 Hardware Setup