Intel BV80605001914AG - Processor - 1 x Xeon X3430 Specification page 49

Specification update
Hide thumbs Also See for BV80605001914AG - Processor - 1 x Xeon X3430:
Table of Contents

Advertisement

AAO99.
VM Exits Due to LIDT/LGDT/SIDT/SGDT Do Not Report Correct
Operand Size
Problem:
When a VM exit occurs due to a LIDT, LGDT, SIDT, or SGDT instruction with a 32-bit
operand, bit 11 of the VM-exit instruction information field should be set to 1. Due to
this erratum, this bit is instead cleared to 0 (indicating a 16-bit operand).
Implication:
Virtual-machine monitors cannot rely on bit 11 of the VM-exit instruction information
field to determine the operand size of the instruction causing the VM exit.
Workaround:
Virtual-machine monitor software may decode the instruction to determine operand
size.
Status:
For the steppings affected, see the Summary Tables of Changes.
AAO100.
PCIConfigRd() and PCIConfigWr() PECI Commands May Silently Fail
During Package C6 Exit Events
Problem:
When PCIConfigRd() or PCIConfigWr() commands coincide with processor package C6
exits under the right timing conditions, they may fail to execute but still produce
'passing' responses.
Implication:
When the timing conditions of this erratum are met, reads will return a value of "all
zeroes" for the return data and writes will have no effect while both commands will
return a passing completion code. The rate of occurrence of this issue is dependent on
frequency and duration of C6 entry/exit events and PECI polling rate.
Workaround:
None identified.
Status:
For the steppings affected, see the Summary Tables of Changes.
AAO101.
Performance Monitoring Events STORE_BLOCKS.NOT_STA and
STORE_BLOCKS.STA May Not Count Events Correctly
Problem:
Performance Monitor Events STORE_BLOCKS.NOT_STA and STORE_BLOCKS.STA
should only increment the count when a load is blocked by a store.
erratum, the count will be incremented whenever a load hits a store, whether it is
blocked or can forward. In addition this event does not count for specific threads
correctly.
Implication:
If Intel® Hyper-Threading Technology is disabled, the Performance Monitor events
STORE_BLOCKS.NOT_STA and STORE_BLOCKS.STA may indicate a higher occurrence
of loads blocked by stores than have actually occurred. If Intel Hyper-Threading
Technology is enabled, the counts of loads blocked by stores may be unpredictable and
they could be higher or lower than the correct count.
Workaround:
None identified.
Status:
For the steppings affected, see the Summary Tables of Changes.
AAO102.
Storage of PEBS Record Delayed Following Execution of MOV SS or STI
Problem:
When a performance monitoring counter is configured for PEBS (Precise Event Based
Sampling), overflow of the counter results in storage of a PEBS record in the PEBS
buffer. The information in the PEBS record represents the state of the next instruction
to be executed following the counter overflow.
overflow occurs after execution of either MOV SS or STI, storage of the PEBS record is
delayed by one instruction.
Implication:
When this erratum occurs, software may observe storage of the PEBS record being
delayed by one instruction following execution of MOV SS or STI. The state information
in the PEBS record will also reflect the one instruction delay.
Workaround:
None identified.
Specification Update
Due to this erratum, if the counter
Due to this
49

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bx80605x3440 - quad core xeon x3440Xeon 3400 series

Table of Contents