Intel BX80570E8200 - Core 2 Duo 2.66 GHz Processor Design Manual

Thermal and mechanical design guidelines
Table of Contents

Advertisement

Quick Links

®
Intel
Core™2 Duo Processor
E8000
and E7000
®
Intel
Pentium
Processor E6000
Series, and Intel
Processor E3x00
Thermal and Mechanical Design Guidelines
August 2009
Series, and
®
Dual-Core
and E5000
®
Celeron
Series
®
Document Number: 318734-011

Advertisement

Table of Contents
loading

Summary of Contents for Intel BX80570E8200 - Core 2 Duo 2.66 GHz Processor

  • Page 1 Core™2 Duo Processor   E8000 and E7000 Series, and ® ® Intel Pentium Dual-Core   Processor E6000 and E5000 ® ® Series, and Intel Celeron  Processor E3x00 Series Thermal and Mechanical Design Guidelines August 2009 Document Number: 318734-011...
  • Page 2 Current roadmap processor number progression is not necessarily representative of future roadmaps. See www.intel.com/products/processor_number for details. Intel, Pentium, Intel Core, Celeron, Intel Inside, and the Intel logo are trademarks of Intel Corporation in the U.S. and other countries.
  • Page 3: Table Of Contents

    Contents Introduction ....................11 Document Goals and Scope ..............11 1.1.1 Importance of Thermal Management ..........11 1.1.2 Document Goals..............11 1.1.3 Document Scope ..............12 References ..................13 Definition of Terms ................13 Processor Thermal/Mechanical Information ............15 Mechanical Requirements ..............15 2.1.1 Processor Package..............15 2.1.2 Heatsink Attach ..............17 2.1.2.1 General Guidelines ............17 2.1.2.2...
  • Page 4 Power Cycling .................47 5.2.3 Recommended BIOS/CPU/Memory Test Procedures ......48 Material and Recycling Requirements ............48 Safety Requirements ................49 Geometric Envelope for Intel Reference BTX Thermal Module Assembly ..49 Preload and TMA Stiffness ..............50 5.6.1 Structural Design Strategy............50 5.6.2 TMA Preload verse Stiffness ............50 ATX Thermal/Mechanical Design Information............53...
  • Page 5 ® Board and System Implementation of Intel QST ........68 ® Intel QST Configuration & Tuning............70 ® Fan Hub Thermistor and Intel QST ............70 Appendix A LGA775 Socket Heatsink Loading ..............71 LGA775 Socket Heatsink Considerations ..........71 Metric for Heatsink Preload for ATX/uATX Designs Non-Compliant ®...
  • Page 6 Figure 5-1. Effective TMA Fan Curves with Reference Extrusion......44 Figure 5-2. Random Vibration PSD ..............46 Figure 5-3. Shock Acceleration Curve..............46 Figure 5-4. Intel Type II TMA 65W Reference Design..........49 Figure 5-5. Upward Board Deflection During Shock ..........50 Figure 5-6. Minimum Required Processor Preload to Thermal Module Assembly Stiffness ..................51...
  • Page 7 Figure 7-50. Reference Fastener - Sheet 1............122 Figure 7-51. Reference Fastener - Sheet 2............123 Figure 7-52. Reference Fastener - Sheet 3............124 Figure 7-53. Reference Fastener - Sheet 4............125 ® Figure 7-54. Intel E18764-001 Reference Solution Assembly ......126 Thermal and Mechanical Design Guidelines...
  • Page 8 Tables Table 2–1. Heatsink Inlet Temperature of Intel Reference Thermal Solutions ...24 Table 2–2. Heatsink Inlet Temperature of Intel Boxed Processor Thermal Solutions ..24 Table 5–1. Balanced Technology Extended (BTX) Type II Reference TMA Performance ...................41 Table 5–2. Acoustic Targets................42 Table 5–3.
  • Page 9 Revision Description Revision Number -001  Initial release. January 2008 ® -002  Added Intel Core™2 Duo processor E8300 and E7200 April 2008 ® -003  Added Intel Core™2 Duo processor E8600 and E7300 August 2008 -004  Added Intel ®...
  • Page 10 Thermal and Mechanical Design Guidelines...
  • Page 11: Introduction

    The concepts given in this document are applicable to any system form factor. Specific examples used will be the Intel enabled reference solution for ATX/uATX systems. See the applicable BTX form factor reference documents to design a thermal solution for that form factor.
  • Page 12: Document Scope

    Chapter 4 addresses the benefits of the processor’s integrated thermal management logic for thermal design. Chapter 5 gives information on the Intel reference thermal solution for the processor in BTX platform. Chapter 6 gives information on the Intel reference thermal solution for the processor in ATX platform.
  • Page 13: References

    Material and concepts available in the following documents may be beneficial when reading this document. Material and concepts available in the following documents may be beneficial when reading this document. Document Location Intel ® Core™2 Duo Processor E8000 and E7000 Series www.intel.com/design/processor/d Datasheet atashts/318732.htm ®...
  • Page 14 Introduction Term Description Sink-to-ambient thermal characterization parameter. A measure of heatsink thermal performance using total package power. This is defined as: (T – T  / Total Package Power.  Note: Heat source must be specified for measurements. Thermal Interface Material: The thermally conductive compound between the heatsink and the processor case.
  • Page 15: Processor Thermal/Mechanical Information

    Processor Thermal/Mechanical Information Processor Thermal/Mechanical Information Mechanical Requirements 2.1.1 Processor Package The processors covered in the document are packaged in a 775-Land LGA package that interfaces with the motherboard using a LGA775 socket. Refer to the datasheet for detailed mechanical specifications. The processor connects to the motherboard through a land grid array (LGA) surface mount socket.
  • Page 16 Processor Thermal/Mechanical Information The primary function of the IHS is to transfer the non-uniform heat distribution from the die to the top of the IHS, out of which the heat flux is more uniform and spread over a larger surface area (not the entire IHS area). This allows more efficient heat transfer out of the package to an attached cooling device.
  • Page 17: Heatsink Attach

    Processor Thermal/Mechanical Information 2.1.2 Heatsink Attach 2.1.2.1 General Guidelines There are no features on the LGA775 socket to directly attach a heatsink: a mechanism must be designed to attach the heatsink directly to the motherboard. In addition to holding the heatsink in place on top of the IHS, this mechanism plays a significant role in the robustness of the system in which it is implemented, in particular: ...
  • Page 18: Additional Guidelines

    Processor Thermal/Mechanical Information 2.1.2.3 Additional Guidelines In addition to the general guidelines given above, the heatsink attach mechanism for the processor should be designed to the following guidelines:  Holds the heatsink in place under mechanical shock and vibration events and applies force to the heatsink base to maintain desired pressure on the thermal interface material.
  • Page 19: Thermal Profile

    The slope of the thermal profile was established assuming a generational improvement in thermal solution performance of the Intel reference design. For an example of Intel Core™2 Duo Processor E8000 series with 6 MB in ATX platform, its improvement is about 15% over the Intel reference design (E18764-001). This performance is expressed as the slope on the thermal profile and can be thought of as the thermal resistance of the heatsink attached to the processor, ...
  • Page 20: Figure 2-3. Example Thermal Profile

    Processor Thermal/Mechanical Information The thermal profiles for the Intel Core™2 Duo processor E8000 series with 6 MB ® cache, Intel Core™2 Duo processor E7000 series with 3 MB cache, and Intel Pentium ® ® dual-core processor E6000 and E5000 series with 2 MB cache, and Intel...
  • Page 21: Heatsink Design Considerations

    This is achieved in part by using the  vs. RPM and RPM vs. Acoustics (dBA) performance curves from the Intel enabled thermal solution. A thermal solution designed to meet the thermal profile would be expected to provide similar acoustic performance of different parts with potentially different T values.
  • Page 22: Heatsink Size

    Processor Thermal/Mechanical Information Passive heatsink solutions require in-depth knowledge of the airflow in the chassis. Typically, passive heatsinks see lower air speed. These heatsinks are therefore typically larger (and heavier) than active heatsinks due to the increase in fin surface required to meet a required performance.
  • Page 23: Package Ihs Flatness

    The attach mechanism (clip, fasteners, etc.) are not included. The mass limit for BTX heatsinks that use Intel reference design structural ingredients is 900 grams. The BTX structural reference component strategy and design is reviewed in depth in the latest version of the Balanced Technology Extended (BTX) System Design Guide.
  • Page 24: System Thermal Solution Considerations

    40° C 35.5° C NOTE: Intel reference designs (E18764-001) for ATX assume the use of the thermally advantaged chassis (refer to Thermally Advantaged Chassis (TAC) Design Guide for TAC thermal and mechanical requirements). The TAC 2.0 Design Guide defines a new processor cooling solution inlet temperature target of 40°...
  • Page 25: Summary

    Socket documentation provides Best Known Methods for all aspects LGA775 socket based platforms and systems manufacturing. Of particular interest for package and heatsink installation and removal is the System Assembly module. A video covering system integration is also available. Contact your Intel field sales representative for further information. §...
  • Page 26 Processor Thermal/Mechanical Information Thermal and Mechanical Design Guidelines...
  • Page 27: Thermal Metrology

    Thermal Metrology Thermal Metrology This section discusses guidelines for testing thermal solutions, including measuring processor temperatures. In all cases, the thermal engineer must measure power dissipation and temperature to validate a thermal solution. To define the performance of a thermal solution the “thermal characterization parameter”,  (“psi”) will be used. Characterizing Cooling Performance Requirements The idea of a “thermal characterization parameter”, ...
  • Page 28: Example

    The following provides an illustration of how one might determine the appropriate performance targets. The example power and temperature numbers used here are not related to any specific Intel processor thermal specifications, and are for illustrative purposes only. Thermal and Mechanical Design Guidelines...
  • Page 29: Processor Thermal Solution Performance Assessment

    Assessment Thermal performance of a heatsink should be assessed using a thermal test vehicle (TTV) provided by Intel. The TTV is a stable heat source that the user can make accurate power measurement, whereas processors can introduce additional factors that can impact test results. In particular, the power level from actual processors varies significantly, even when running the maximum power application provided by Intel, due to variances in the manufacturing process.
  • Page 30 Thermal Metrology determination of the localized air temperature around the processor during system thermal testing. For active heatsinks, it is important to avoid taking measurement in the dead flow zone that usually develops above the fan hub and hub spokes. Measurements should be taken at four different locations uniformly placed at the center of the annulus formed by the fan hub and the fan housing to evaluate the uniformity of the air temperature at the fan inlet.
  • Page 31: Figure 3-2. Locations For Measuring Local Ambient Temperature, Active Atx

    Thermal Metrology Figure 3-2. Locations for Measuring Local Ambient Temperature, Active ATX Heatsink Note: Drawing Not to Scale Figure 3-3. Locations for Measuring Local Ambient Temperature, Passive Heatsink Note: Drawing Not to Scale Thermal and Mechanical Design Guidelines...
  • Page 32: Processor Case Temperature Measurement Guidelines

    Thermal Metrology Processor Case Temperature Measurement Guidelines To ensure functionality and reliability, the processor is specified for proper operation when T is maintained at or below the thermal profile as listed in the datasheet. The measurement location for T is the geometric center of the IHS. Figure 2-2 shows the location for T measurement.
  • Page 33: Thermal Management Logic And Thermal Monitor Feature

    In the absence of power saving technologies, ever increasing frequencies will result in processors with power dissipations in the hundreds of watts. Fortunately, there are numerous ways to reduce the power consumption of a processor, and Intel is aggressively pursuing low power design techniques. For example, decreasing the operating voltage, reducing unnecessary transistor activity, and using more power efficient circuits can significantly reduce processor power consumption.
  • Page 34: Prochot# Signal

    Thermal Management Logic and Thermal Monitor Feature 4.2.1 PROCHOT# Signal The primary function of the PROCHOT# signal is to provide an external indication that the processor has reached the TCC activation temperature. While PROCHOT# is asserted, the TCC will be activated. Assertion of the PROCHOT# signal is independent of any register settings within the processor.
  • Page 35: Thermal Monitor 2

    Thermal Management Logic and Thermal Monitor Feature Figure 4-1. Thermal Monitor Control PROCHOT# Normal clock Internal clock Duty cycle control Resultant internal clock 4.2.3 Thermal Monitor 2 The second method of power reduction is TM2. TM2 provides an efficient means of reducing the power consumption within the processor and limiting the processor temperature.
  • Page 36: Operation And Configuration

    Thermal Management Logic and Thermal Monitor Feature Once the processor has sufficiently cooled, and a minimum activation time has expired, the operating frequency and voltage transition back to the normal system operating point. Transition of the VID code will occur first, in order to insure proper operation once the processor reaches its normal operating frequency.
  • Page 37: On-Demand Mode

    4.2.6 System Considerations Intel requires the Thermal Monitor and Thermal Control Circuit to be enabled for all processors. The thermal control circuit is intended to protect against short term thermal excursions that exceed the capability of a well designed processor thermal solution.
  • Page 38: Operating System And Application Software Considerations

    Thermal Management Logic and Thermal Monitor Feature A system designed to meet the thermal profile specification published in the processor datasheet greatly reduces the probability of real applications causing the thermal control circuit to activate under normal operating conditions. Systems that do not meet these specifications could be subject to more frequent activation of the thermal control circuit depending upon ambient air temperature and application power profile.
  • Page 39: Platform Environmental Control Interface (Peci)

    Set Overview. For additional information on the PECI see the datasheet. The PECI bus is available on pin G5 of the LGA 775 socket. Intel chipsets beginning with the ICH8 have included PECI host controller. The PECI interface and the ®...
  • Page 40 QST), see Chapter 7 and the Intel Quiet System Technology Configuration and Tuning Manual. Intel has worked with many vendors that provide fan speed control devices to provide PECI host controllers. Consult the local representative for your preferred vendor for their product plans and availability.
  • Page 41: Balanced Technology Extended (Btx) Thermal/Mechanical Design Information

    The difference in Ψ ca between the Intel Core™2 Duo processor E8000 series with ® 6 MB cache, Intel Core™2 Duo processor E7000 series with 3 MB cache, Intel Pentium dual-core processor E6000, E5000 series with 2 MB cache, and Intel ®...
  • Page 42: Acoustics

    Using the example in Table 5–2 for the Intel Core™2 Duo processor with 4 MB cache at Tc-max of 60.1° C the required fan speed necessary to meet thermal specifications can be controlled by the fan inlet temperature and should comply with requirements in the following table.
  • Page 43: Effective Fan Curve

    Balanced Technology Extended (BTX) Thermal/Mechanical Design Information 5.1.3 Effective Fan Curve The TMA must fulfill the processor cooling requirements shown in Table 5–1 when it is installed in a functional BTX system. When installed in a system, the TMA must operate against the backpressure created by the chassis impedance (due to vents, bezel, peripherals, etc…) and will operate at lower net airflow than if it were tested outside of the system on a bench top or open air environment.
  • Page 44: Voltage Regulator Thermal Management

    VR power is not at a maximum or if the external ambient temperature is less than 35 ºC. This recommended airflow rate is based on the requirements for the Intel 965 Express Chipset Family. Thermal and Mechanical Design Guidelines...
  • Page 45: Altitude

    5.1.6 Reference Heatsink Thermal Validation The Intel reference heatsink will be validated within the specific boundary conditions based on the methodology described Section 5.2 , and using a thermal test vehicle. Testing is done in a BTX chassis at ambient lab temperature. The test results, for a number of samples, will be reported in terms of a worst-case mean + 3...
  • Page 46: Shock Test Procedure

    Balanced Technology Extended (BTX) Thermal/Mechanical Design Information Figure 5-2. Random Vibration PSD Vibration System Level + 3 dB Control Limit 0.01 - 3 dB Control Limit 0.001 0.0001 1000 5.2.1.2 Shock Test Procedure Recommended performance requirement for a system:  Quantity: 2 drops for + and - directions in each of 3 perpendicular axes (i.e., total 12 drops).
  • Page 47: Power Cycling

    Balanced Technology Extended (BTX) Thermal/Mechanical Design Information 5.2.1.2.1 Recommended Test Sequence Each test sequence should start with components (i.e., motherboard, heatsink assembly, etc.) that have never been previously submitted to any reliability testing. The test sequence should always start with a visual inspection after assembly, and BIOS/CPU/Memory test (refer to Section 6.3.3).
  • Page 48: Recommended Bios/Cpu/Memory Test Procedures

    Balanced Technology Extended (BTX) Thermal/Mechanical Design Information 5.2.3 Recommended BIOS/CPU/Memory Test Procedures This test is to ensure proper operation of the product before and after environmental stresses, with the thermal mechanical enabling components assembled. The test shall be conducted on a fully operational motherboard that has not been exposed to any battery of tests prior to the test being considered.
  • Page 49: Safety Requirements

    BTX Interface Specification for Zone A, found at http://www.formfactors.org. Figure 5-4. Intel Type II TMA 65W Reference Design Development vendor information for the Intel Type II TMA Reference Solution is provided in Appendix H. Thermal and Mechanical Design Guidelines...
  • Page 50: Preload And Tma Stiffness

    5.6.1 Structural Design Strategy Structural design strategy for the Intel Type II TMA is to minimize upward board deflection during shock to help protect the LGA775 socket. BTX thermal solutions use the SRM and TMA that together resists local board curvature under the socket and minimize, board deflection (Figure 5-5).
  • Page 51: Figure 5-6. Minimum Required Processor Preload To Thermal Module Assembly

    Balanced Technology Extended (BTX) Thermal/Mechanical Design Information Table 5–4, then the Thermal Module should be re-designed to have a preload that lies within the range given in Table 5–4, allowing for preload tolerances. Table 5–4. Processor Preload Limits Maximum Parameter Minimum Required Notes Allowed...
  • Page 52: Figure 5-7. Thermal Module Attach Pointes And Duct-To-Srm Interface Features

    (SRM) Design Guide. For TMA mounting schemes that use only the motherboard mounting hole position for TMA attach, the required preload is approximately 10–15N greater than the values stipulated in Figure 5-6; however, Intel has not conducted any validation testing with this TMA mounting scheme.
  • Page 53: Atx Thermal/Mechanical Design Information

    This chapter will document the requirements for an active air-cooled design, with a fan installed at the top of the heatsink. The thermal technology required for the processor. The Intel Core™2 Duo processor E8000, E7000 series, Intel Pentium dual-core ® ®...
  • Page 54: Figure 6-1. E18764-001 Reference Design - Exploded View

    ATX Thermal/Mechanical Design Information Figure 6-1. E18764-001 Reference Design – Exploded View Figure 6-2. Bottom View of Copper Core Applied by TC-1996 Grease The ATX motherboard keep-out and the height recommendations defined Section 6.6 remain the same for a thermal solution for the processor in the 775-Land LGA package.
  • Page 55: Validation Results For Reference Design

    Performance targets (Ψ ca) as measured with a live processor at TDP. The difference in Ψ ca between the Intel Core™2 Duo processor E8000 series with 6 MB cache and Intel Core™2 Duo processor E7000 series with 3 MB cache, Intel ®...
  • Page 56: Acoustics

    4 Wire PWM Controlled to implement fan speed control capability based digital thermal sensor temperature. Refer to Chapter 7 for further details. Note: Appendix F gives detailed fan performance for the Intel reference thermal solutions with 4 Wire PWM Controlled fan.
  • Page 57: Heatsink Thermal Validation

    6.2.4 Heatsink Thermal Validation Intel recommends evaluation of the heatsink within the specific boundary conditions based on the methodology described Section 6.3 , and using a thermal test vehicle. Testing is done on bench top test boards at ambient lab temperature. In particular, for the reference heatsink, the Plexiglas* barrier is installed 81.28 mm [3.2 in] above the...
  • Page 58: Shock Test Procedure

    ATX Thermal/Mechanical Design Information Figure 6-3. Random Vibration PSD 3.13GRMS (10 minutes per axis) (20, 0.02) (500, 0.02) (5, 0.01) 0.01 5 Hz 500 Hz 0.001 1000 Frequency (Hz) 6.3.1.2 Shock Test Procedure Recommended performance requirement for a motherboard:  Quantity: 3 drops for + and - directions in each of 3 perpendicular axes (i.e., total 18 drops).
  • Page 59: Power Cycling

    ATX Thermal/Mechanical Design Information 6.3.1.2.1 Recommended Test Sequence Each test sequence should start with components (i.e. motherboard, heatsink assembly, etc.) that have never been previously submitted to any reliability testing. The test sequence should always start with a visual inspection after assembly, and BIOS/CPU/Memory test (refer to Section 6.3.3).
  • Page 60: Recommended Bios/Cpu/Memory Test Procedures

    ATX Thermal/Mechanical Design Information 6.3.3 Recommended BIOS/CPU/Memory Test Procedures This test is to ensure proper operation of the product before and after environmental stresses, with the thermal mechanical enabling components assembled. The test shall be conducted on a fully operational motherboard that has not been exposed to any battery of tests prior to the test being considered.
  • Page 61: Safety Requirements

    If the International Accessibility Probe specified in IEC 950 can access the moving parts of the fan, consider adding safety feature so that there is no risk of personal injury. Geometric Envelope for Intel Reference ATX Thermal Mechanical Design Figure 7-40, Figure 7-41, and Figure 7-42 in Appendix G gives detailed reference ATX/μATX motherboard keep-out information for the reference thermal/mechanical...
  • Page 62: Reference Attach Mechanism

    191.3 N ± 44.5 N [43 lb ± 10 lb]. Note: Intel reserves the right to make changes and modifications to the design as necessary to the reference design, in particular the clip and fastener.
  • Page 63: Mechanical Interface To The Reference Attach Mechanism

    ATX Thermal/Mechanical Design Information 6.7.2 Mechanical Interface to the Reference Attach Mechanism The attach mechanism component from the reference design can be used by other 3 party cooling solutions. The attach mechanism consists of:  A metal attach clip that interfaces with the heatsink core, see Appendix G, Figure 7-48 and Figure 7-49 for the component drawings.
  • Page 64: Figure 6-7. Critical Parameters For Interfacing To Reference Clip

    ATX Thermal/Mechanical Design Information Figure 6-7. Critical Parameters for Interfacing to Reference Clip Fin Array Fin Array Core Core See Detail A See Detail A Clip Clip Fin Array Fin Array Fin Array Fin Array Fin Array Fin Array 1.6 mm 1.6 mm 1.6 mm 1.6 mm...
  • Page 65: Intel Quiet System Technology (Intel Qst)

    The ME provides integrated fan speed control in lieu of the mechanisms available in a SIO or a stand-alone ASIC. The Intel QST is time based as compared to the linear or state control used by the current generation of FSC devices.
  • Page 66: Output Weighting Matrix

    7.1.1 Output Weighting Matrix Intel QST provides an Output Weighting Matrix that provides a means for a single thermal sensor to affect the speed of multiple fans. An example of how the matrix could be used is if a sensor located next to the memory is sensitive to changes in both the processor heatsink fan and a 2 fan in the system.
  • Page 67: Figure 7-2. Pid Controller Fundamentals

    Intel® Quiet System Technology (Intel® QST) target temperature. As a result of its operation, the PID control algorithm can enable an acoustic-friendly platform. Figure 7-2. PID Controller Fundamentals Integral (time averaged) Integral (time averaged) Integral (time averaged) Integral (time averaged)
  • Page 68: Board And System Implementation Of Intel

    To implement the board must be configured as shown in Figure 7-3 and listed below:  ME system (S0–S1) with Controller Link connected and powered  DRAM with Channel A DIMM 0 installed and 2 MB reserved for Intel QST FW execution  SPI Flash with sufficient space for the Intel QST Firmware ...
  • Page 69: Figure 7-4. Example Acoustic Fan Speed Control Implementation

    Figure 7-4. Example Acoustic Fan Speed Control Implementation Intel has engaged with a number of major manufacturers of thermal / voltage sensors to provide devices for the SST bus. Contact your Intel Field Sales representative for the current list of manufacturers and visit their web sites or local sales representatives for a part suitable for your design.
  • Page 70: Intel Qst Configuration & Tuning

    ® Fan Hub Thermistor and Intel There is no closed loop control between Intel QST and the thermistor, but they can work in tandem to provide the maximum fan speed reduction. The BTX reference design includes a thermistor on the fan hub. This Variable Speed Fan curve will determine the maximum fan speed as a function of the inlet ambient temperature and by design provides a ...
  • Page 71: Appendix Alga775 Socket Heatsink Loading

    Mechanical shock and vibration and TIM performance AND LGA775 socket protection against fatigue failure. Metric for Heatsink Preload for ATX/uATX ® Designs Non-Compliant with Intel Reference Design Heatsink Preload Requirement Limitations Heatsink preload by itself is not an appropriate metric for solder joint force across...
  • Page 72: Motherboard Deflection Metric Definition

    LGA775 Socket Heatsink Loading Simulation shows that the solder joint force (F axial ) is proportional to the board deflection measured along the socket diagonal. The matching of F axial required to protect the LGA775 socket solder joint in temperature cycling is equivalent to matching a target MB deflection.
  • Page 73: Board Deflection Limits

    LGA775 Socket Heatsink Loading Figure 7-6. Board Deflection Definition d’1 d’2 A.3.2 Board Deflection Limits Deflection limits for the ATX/µATX form factor are: d_BOL – d_ref≥ 0.09 mm and d_EOL – d_ref ≥ 0.15 mm d’_BOL – d’_ref≥ 0.09 mm and d_EOL’ – d_ref’ ≥ 0.15 mm NOTES: The heatsink preload must remain within the static load limits defined in the processor datasheet at all times.
  • Page 74: Board Deflection Metric Implementation Example

    LGA775 Socket Heatsink Loading A.3.3 Board Deflection Metric Implementation Example This section is for illustration only, and relies on the following assumptions:  72 mm x 72 mm hole pattern of the reference design  Board stiffness = 900 lb/in at BOL, with degradation that simulates board creep over time ...
  • Page 75: Additional Considerations

    Figure 7-7. Example: Defining Heatsink Preload Meeting Board Deflection Limit A.3.4 Additional Considerations Intel recommends to design to {d_BOL - d_ref = 0.15mm} at BOL when EOL conditions are not known or difficult to assess The following information is given for illustration only. It is based on the reference keep-out, assuming there is no fixture that changes board stiffness: d_ref is expected to be 0.18 mm on average, and be as high as 0.22 mm...
  • Page 76: Motherboard Stiffening Considerations

    The Boxed Processor  The reference design (E18764-001) Intel will collaborate with vendors participating in its third party test house program to evaluate third party solutions. Vendor information now is available in Intel Core™2 Duo Processor Support Components webpage www.intel.com/go/thermal_Core2Duo §...
  • Page 77: Appendix B Heatsink Clip Load Metrology

    For example: • Heatsink preload for the LGA775 socket • Quantify preload degradation under bake conditions. Note: This document reflects the current metrology used by Intel. Intel is continuously exploring new ways to improve metrology. Test Preparation B.2.1 Heatsink Preparation...
  • Page 78: Figure 7-8. Load Cell Installation In Machined Heatsink Base Pocket - Bottom View

    Heatsink Clip Load Metrology Remarks: Alternate Heatsink Sample Preparation As mentioned above, making sure that the load cells have minimum protrusion out of the heatsink base is paramount to meaningful results. An alternate method to make sure that the test setup will measure loads representative of the non-modified design ...
  • Page 79: Figure 7-9. Load Cell Installation In Machined Heatsink Base Pocket - Side View

    Heatsink Clip Load Metrology Figure 7-9. Load Cell Installation in Machined Heatsink Base Pocket – Side View Wax to maintain load cell in position during heatsink installation Height of pocket ~ height of selected load cell Load cell protrusion (Note: to be optimized depending on assembly stiffness) Figure 7-10.
  • Page 80: Typical Test Equipment

    Heatsink Clip Load Metrology B.2.2 Typical Test Equipment For the heatsink clip load measurement, use equivalent test equipment to the one listed in Table 7–2. Table 7–2. Typical Test Equipment Part Number Item Description (Model) Load cell Honeywell*-Sensotec* Model 13 subminiature AL322BL load cells, compression only Notes: 1, 5...
  • Page 81: Time-Zero, Room Temperature Preload Measurement

    Heatsink Clip Load Metrology B.3.1 Time-Zero, Room Temperature Preload Measurement 1. Pre-assemble mechanical components on the board as needed prior to mounting the motherboard on an appropriate support fixture that replicate the board attach to a target chassis  For example: standard ATX board should sit on ATX compliant stand-offs. If the attach mechanism includes fixtures on the back side of the board, those must be included, as the goal of the test is to measure the load provided by the actual heatsink mechanism.
  • Page 82 Heatsink Clip Load Metrology Thermal and Mechanical Design Guidelines...
  • Page 83: Appendix C Thermal Interface Management

    Thermal Interface Management Appendix C Thermal Interface Management To optimize a heatsink design, it is important to understand the impact of factors related to the interface between the processor and the heatsink base. Specifically, the bond line thickness, interface material area and interface material thermal conductivity should be managed to realize the most effective thermal solution.
  • Page 84 Thermal Interface Management § Thermal and Mechanical Design Guidelines...
  • Page 85: Case Temperature Reference Metrology

    The following supplier can do machining the groove and attaching a thermocouple to the IHS followed by the reference procedure. The supplier is listed the table below as a convenience to Intel’s general customers and the list may be subject to change without notice.
  • Page 86: Figure 7-11. Omega Thermocouple

    Case Temperature Reference Metrology Item Description Part Number Miscellaneous Hardware Solder Indium Corp. of America 52124 Alloy 57BI / 42SN / 1AG 0.010 Diameter Flux Indium Corp. of America 5RMA Loctite* 498 Super glue w/thermal characteristics 49850 Adhesive Adhesive Loctite* 7452 for fast glue curing 18490 Accelerator Kapton* Tape...
  • Page 87: Thermal Calibration And Controls

    It is recommended to follow company standard procedures and wear safety items like glasses for cutting the IHS and gloves for chemical handling. Ask your Intel field sales representative if you need assistance to groove and/or install a thermocouple according to the reference process.
  • Page 90: Figure 7-14. Ihs Groove At 6 O'clock Exit On The 775-Land Lga Package

    Case Temperature Reference Metrology The orientation of the groove at 6 o’clock exit relative to the package pin 1 indicator (gold triangle in one corner of the package) is shown in Figure 7-14 for the 775-Land LGA package IHS. Figure 7-14. IHS Groove at 6 o’clock Exit on the 775-LAND LGA Package IHS Groove Pin1 indicator When the processor is installed in the LGA775 socket, the groove is parallel to the...
  • Page 91: Thermocouple Attach Procedure

    Case Temperature Reference Metrology Thermocouple Attach Procedure The procedure to attach a thermocouple with solder takes about 15 minutes to complete. Before proceeding turn on the solder block heater, as it can take up to 30 minutes to reach the target temperature of 153 – 155° C. Note: To avoid damage to the processor ensure the IHS temperature does not exceed 155°...
  • Page 92: Thermocouple Attachment To The Ihs

    Case Temperature Reference Metrology Figure 7-17. Bending the Tip of the Thermocouple D.5.2 Thermocouple Attachment to the IHS 6. Clean groove and IHS with Isopropyl Alcohol (IPA) and a lint free cloth removing all residues prior to thermocouple attachment. 7. Place the thermocouple wire inside the groove; letting the exposed wire and bead extend about 1.5 mm [0.030 inch] past the end of groove.
  • Page 93: Figure 7-19. Thermocouple Bead Placement

    Case Temperature Reference Metrology Figure 7-19. Thermocouple Bead Placement 10. Place the package under the microscope to continue with process. It is also recommended to use a fixture (like processor tray or a plate) to help holding the unit in place for the rest of the attach process. 11.
  • Page 94: Figure 7-20. Position Bead On The Groove Step

    Case Temperature Reference Metrology Figure 7-20. Position Bead on the Groove Step Wire section Kapton* into the tape groove to prepare for final bead placement Figure 7-21. Detailed Thermocouple Bead Placement TC Bead TC Wire with Insulation IHS with Groove Figure 7-22.
  • Page 95: Figure 7-23. Measuring Resistance Between Thermocouple And Ihs

    Case Temperature Reference Metrology 12. Place a 3 piece of tape at the end of the step in the groove as shown in Figure 7-22. This tape will create a solder dam to prevent solder from flowing into the larger IHS groove section during the melting process. 13.
  • Page 96: Figure 7-24. Applying Flux To The Thermocouple Bead

    Case Temperature Reference Metrology Figure 7-24. Applying Flux to the Thermocouple Bead 15. Cut two small pieces of solder 1/16 inch (0.065 inch / 1.5 mm) from the roll using tweezers to hold the solder while cutting with a fine blade (Figure 7-25). Figure 7-25.
  • Page 97: Solder Process

    Case Temperature Reference Metrology Figure 7-26. Positioning Solder on IHS 17. Measure the resistance from the thermocouple end wires again using the DMM (refer to Section D.5.1.step 2) to ensure the bead is still properly contacting the IHS. D.5.3 Solder Process 18.
  • Page 98: Figure 7-27. Solder Station Setup

    Case Temperature Reference Metrology Figure 7-27. Solder Station Setup 21. Remove the land side protective cover and place the device to be soldered in the solder station. Make sure the thermocouple wire for the device being soldered is exiting the heater toward you. Note: Do not touch the copper heater block at any time as this is very hot.
  • Page 99: Figure 7-28. View Through Lens At Solder Station

    Case Temperature Reference Metrology Figure 7-28. View Through Lens at Solder Station Figure 7-29. Moving Solder back onto Thermocouple Bead Thermal and Mechanical Design Guidelines...
  • Page 100: Cleaning & Completion Of Thermocouple Installation

    Case Temperature Reference Metrology 25. Lift the heater block and magnified lens, using tweezers quickly rotate the device 90 degrees clockwise. Using the back of the tweezers press down on the solder this will force out the excess solder. Figure 7-30. Removing Excess Solder 26.
  • Page 101: Figure 7-31. Thermocouple Placed Into Groove

    Case Temperature Reference Metrology Figure 7-31. Thermocouple placed into groove 29. Using a blade carefully shave the excess solder above the IHS surface. Only shave in one direction until solder is flush with the groove surface (Figure 7-32). Figure 7-32. Removing Excess Solder Note: Take usual precautions when using open blades 30.
  • Page 102: Figure 7-33. Filling Groove With Adhesive

    Case Temperature Reference Metrology Figure 7-33. Filling Groove with Adhesive 32. To speed up the curing process apply Loctite* Accelerator on top of the Adhesive and let it set for a couple of minutes (Figure 7-34). Figure 7-34. Application of Accelerant Thermal and Mechanical Design Guidelines...
  • Page 103: Figure 7-35. Removing Excess Adhesive From Ihs

    Case Temperature Reference Metrology Figure 7-35. Removing Excess Adhesive from IHS 33. Using a blade, carefully shave any adhesive that is above the IHS surface (Figure 7-35). The preferred method is to shave from the edge to the center of the IHS.
  • Page 104: Thermocouple Wire Management

    Case Temperature Reference Metrology Thermocouple Wire Management When installing the processor into the socket, the thermocouple wire should route under the socket lid, as Figure 7-37. This will keep the wire from getting damaged or pinched when removing and installing the heatsink. Note: When thermocouple wires are damaged, the resulting reading maybe wrong.
  • Page 105: Appendix E Balanced Technology Extended (Btx) System Thermal Considerations

    Balanced Technology Extended (BTX) System Thermal Considerations Appendix E Balanced Technology Extended (BTX) System Thermal Considerations There are anticipated system operating conditions in which the processor power may be low but other system component powers may be high. If the only Fan Speed Control (FSC) circuit input for the Thermal Module Assembly (TMA) fan is from the processor sensor then the fan speed and system airflow is likely to be too low in this operating state.
  • Page 106: Figure 7-38. System Airflow Illustration With System Monitor Point Area Identified

    Balanced Technology Extended (BTX) System Thermal Considerations The thermal sensor location and elevation are reflected in the Flotherm thermal model airflow illustration and pictures (see Figure 7-38 and Figure 7-39).The Intel Boxed Boards in BTX form factor have implemented a System Monitor thermal sensor. The...
  • Page 107: Figure 7-39. Thermal Sensor Location Illustration

    Balanced Technology Extended (BTX) System Thermal Considerations Figure 7-39. Thermal sensor Location Illustration Thermal Sensor MCH Heatsink § Thermal and Mechanical Design Guidelines...
  • Page 108 Balanced Technology Extended (BTX) System Thermal Considerations Thermal and Mechanical Design Guidelines...
  • Page 109: Appendix F Fan Performance For Reference Design

    Fan Performance for Reference Design Appendix F Fan Performance for Reference Design The fan power requirements for proper operation are given Table 7–3. Table 7–3. Fan Electrical Performance Requirements Requirement Value Maximum Average fan current draw 1.5 A Fan start-up current draw 2.2 A Fan start-up current draw maximum 1.0 second...
  • Page 110 Fan Performance for Reference Design Thermal and Mechanical Design Guidelines...
  • Page 111: Appendix G Mechanical Drawings

    The following table lists the mechanical drawings included in this appendix. These drawings refer to the reference thermal mechanical enabling components for the processor. Note: Intel reserves the right to make changes and modifications to the design as necessary. Drawing Description Page Number ATX/µATX Motherboard Keep-out Footprint Definition and Height...
  • Page 112 47.50 45.26 40.00 39.01 36.78 36.00 32.51 27.81 27.51 23.47 7.30 2 0.00 5.90 ) 16.87 23.47 27.00 27.51 32.51 36.49 33.00 36.78 36.00 40.00 39.01 44.00 45.26 47.50...
  • Page 126 DWG. NO. REV.
  • Page 127: Intel Enabled Reference Solution Information

    The following tables list suppliers that produce Intel enabled reference components. The part numbers listed below identifies these reference components. End-users are responsible for the verification of the Intel enabled component offerings with the supplier. OEMs and System Integrators are responsible for thermal, mechanical, and environmental validation of these solutions.
  • Page 128: Table 7-6. Btx Reference Thermal Solution Providers

    Intel® Enabled Reference Solution Information Note: These vendors and devices are listed by Intel as a convenience to Intel's general customer base, but Intel does not make any representations or warranties whatsoever regarding quality, reliability, functionality, or compatibility of these devices. This list and/or these devices may be subject to change without notice.

Table of Contents