Rev. 5/95
3.4 MANUAL ID CONTROL
Manual ID Level
1
2
3
4
5
6
7
3.4.1 Manual ID Control
The user can select one of 14 manual ID levels. For each level, the intensity of
the light output by the exposure lamp (as measured by the light sensor) varies.
This is shown in the above table. The development roller bias also varies. (See
the section on development bias.)
SM
Light Sensor
Output [V]
0.78
0.892
0.899
0.938
1.02
1.24
1.45
2-12
Manual ID Level
8
9
10
11
12
13
14
Light Sensor
Output [V]
1.53
1.73
1.93
2.13
2.33
2.52
2.72
A163