2.
SERVICE TABLES
2.1
TEST POINTS
Main Board
Number
TP101
V
(+24V)
AA
TP102
Vcc (+5V)
TP103
GND
TP104
Toner density sensor (CN104-A10)
TP105
Light sensor output (CN104-B1)
Charge/Bias/Grid Power Pack
Number
TP1
Development Bias Voltage
TP2
Grid Voltage
2.2
VARIABLE RESISTORS
Charge/Bias/Grid Power Pack
Number
VR1
Charge Corona Voltage
Caution: VR1 should not be changed in the field. Charge corona can be
adjusted using SP #--10.
T&S Power Pack
Number
VRT
Transfer Corona Voltage
VRD (DC) Separation Corona Voltage (DC)
VRD (AC) Separation Corona Voltage (AC)
Caution: VRT, VRD (DC), and VRD (AC) should not be changed in the field.
They can be adjusted using SP #--12 to --17.
SM
Function
Function
Function
Function
4-7
A163