Temperature Control; Hot Roller Temperature Control - Ricoh FW780 Service Manual

Service manual
Hide thumbs Also See for FW780:
Table of Contents

Advertisement

FUSING AND PAPER EXIT

2.8.3 TEMPERATURE CONTROL

Hot Roller Temperature Control

Hot Roller Temp. (°C)
1 9 8
1 9 0
Mode 5
1 8 0
Mode 3
1 7 0
Mode 1
1 6 0
1 5 0
1 4 2
~ 6 0
6 3 6 6 6 9 7 2 7 5 7 8 8 1 8 4 8 7 9 0 9 3 9 6 9 9 1 0 2 1 0 5 1 0 8 1 1 1 1 1 4 1 1 7 1 2 0 ~
1 9 8
1 9 0
1 8 5
1 8 0
1 1 0
Lower Limit
The relationship between the hot roller and pressure roller temperatures has been
changed due to the thin-shell, Teflon coated roller.
B047/B048
Mode 8
Mode 7
Mode 6
Mode 4
Mode 2
Mode 8
1 1 5
1 2 0
1 2 5
1 3 0
1 3 5
1 4 0
2-8
Pressure Roller Temp. (°C)
Operating Temperature
Lower Limit
1 4 5
B047D001.WMF
SM