Service Call Condition; Sc Code E-1: Exposure Lamp Abnormal; Sc Code E-2: Fusing Thermofuse Open - Ricoh FW780 Service Manual

Service manual
Hide thumbs Also See for FW780:
Table of Contents

Advertisement

2. SERVICE CALL CONDITION

When a service call condition occurs, the Call Service indicator
and service
call codes are displayed.
When the service call conditions E2, E3, E4, E5, E6, E7, and E8 conditions occur,
for safety reason they cannot be cleared by turning the main switch off and on.
Accessing SP38 and changing the date from "1" to "0" must be done to clear
these service call conditions.

2.1 SC Code E-1: Exposure Lamp Abnormal

-Definition-
The light sensor voltage is less than 0.4 volts for 10 seconds.
<Points to check>
Exposure lamp
Light sensor
FL regulator (CN402-1,2,4, and 5, CN401-1, -2, -4)
Main board (CN106-A3, and CN104-B1, -B2, -A29 -A30)

2.2 SC Code E-2: Fusing Thermofuse Open

-Definition-
The temperature detected by the hot roller thermistor does not reach 100 C within
4 minutes and 30 seconds after the main switch is turned on.
<Point to check>
Fusing thermofuse
Hot roller thermistor
AC drive board (T202-2, RA201-T4)
Main board (CN106-A2, A4, B12, B14, B15)
SM
6-7
A163