T & S Corona Unit; T & S Corona Unit Removal - Ricoh FW780 Service Manual

Service manual
Hide thumbs Also See for FW780:
Table of Contents

Advertisement

6.
T & S CORONA UNIT
6.1
T & S CORONA UNIT REMOVAL
[B]
1. Open the paper path section [A] and take out the T & S corona unit [B] (2
connectors [C]).
NOTE: 1) Make sure that the T & S corona unit is set correctly by pressing it
down when reinstalling.
2) Remove the connector cover [D] (1screw) for connecting the 2
connectors.
SM
[A]
[C]
5-33
[C]
[D]
A163