SERVICE CALL CONDITIONS
SC Code E-4: Hot Roller Thermistor Short
Definition
The resistance of the hot roller thermistor is less than 0.11 K .
Points to Check
Hot roller thermistor
Main board (CN102-A5, -B11, -B13, -B14)
SC Code E-5: Pressure Roller Thermistor Open
Definition
The resistance of the pressure roller thermistor is more than 0.53 M .
Points to Check
Pressure roller thermistor
Main board (CN102-A4, -B12, -B13, -B14)
SC Code E-6: Pressure Roller Thermistor Short
Definition
The resistance of the pressure roller thermistor is less than 0.55 K .
Points to check
Pressure roller thermistor
Main board (CN102-A4, -B12, -B13, -B14)
SC Code E-7: Fusing Overheat
Definition
The temperature detected by the hot roller thermistor exceeds 250 C.
Points to Check
Hot roller thermistor
Fusing thermofuse
AC drive board
Main board (CN102-A1, -B13, -B14)
B047/B048
6-2
11 May, 2001
SM