2 Troubleshooting Procedures
AC Adaptor
Error code
10h
11h
12h
13h
14h
1st Battery
Error code
22h
23h
24h
25h
2nd Battery
Error code
32h
33h
34h
35h
S3V output
Error code
40h
45h
46h
2-10
[CONFIDENTIAL]
AC Adaptor output voltage is over 16.5V.
CommonDock voltage is over 16.5V.
Current from the DC power supply is over 7.00A.
Current from the DC power supply is over 0.5A when there is no load.
Correction value of 0[A] is out of designed value.
1st battery discharge current over 0.5A when there is no load.
1st battery charge current is over 3.9A in charging.
Correction value of 0[A] is out of designed value.
1st battery charge current is over 0.3A in not charging.
2nd battery discharge current is over 0.5A when there is no load.
2nd battery charge current is over 3.9A in charging.
Correction value of 0[A] is out of designed value.
2nd battery charge current is over 0.3A in not charging.
S3V voltage is 3.47V or less when the computer is powered on/off.
S3V voltage is under 3.14V in normal conditions.
S3V voltage is under 3.14V when the computer is booting up.