CONVERSION KIT FROM NATURAL GAS TO PROPANE MODEL #512-969
FOR P36D USING SIT 820 NOVA GAS VALVE
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
IF IN DOUBT DO NOT DO THIS CONVERSION !!
Conversion Kit Contains:
Qty. Part #
Description
1
910-018
SIT Conversion Kit-50%
Turndown LP
1
910-037
LP Injector (Pilot Orifice)
1
904-390
Burner Orifice #52
1
908-255
Decal "Converted to Propane"
1
908-528
Red "PROPANE" label
1
918-013
LP Conversion Decal (not
required for P90)
1
908-529
5/32" Allen Key
1
908-793
Instruction Sheet
1) Shut off the gas supply.
2) Remove the louvers (and bay door if it is
installed).
3) Open the flush door and remove the door.
4) Remove the logs, embers, and brick panels
(if used).
5) Remove the 2 screws holding the Burner
Assembly to the firebox base. Push the
Burner Assembly to the left and lift out.
Remove the 2 screws, push Burner
Assembly to the left and lift out.
6) Pull off the pilot cap to expose the pilot
orifice.
7) Unscrew the pilot orifice with the allen key
and replace with the LP pilot orifice in the kit
and replace pilot cap.
FPI P36D Zero Clearance Direct Vent Gas Fireplace
8) Remove burner orifice with a 1/2" wrench
and discard. Use another wrench to hold
on to the elbow behind the orifice.
Burner Orifice
9) Reinstall new burner orifice LP stamped #52
and tighten.
10) Remove and discard the 3 pressure regu-
lator mounting screws (A), pressure regu-
lator tower (B) and diaphragm (C).
11) Insure that the rubber gasket (D) is properly
positioned and install the new HI/LO pres-
sure regulator assembly to the valve using
the new screws (E) supplied with the kit.
Tighten screws securely.
12) Reverse steps 5) to 2).
13) Attach clear label "This unit has been con-
verted to Propane" near or on the serial #
decal. Attach white label "This valve has
been converted from NG to LPG using SIT
conversion Kit Code 0.907.202" onto the
valve.
14) Replace yellow "Natural Gas" label with red
"Propane" label
15) Check for gas leaks.
16) Check inlet and outlet pressures.
17) Check operation of flame control.
18) Check for proper flame appearance and
glow on logs.
INSTALLATION