P36d zero clearance direct vent gas fireplace
Table of Contents

Advertisement

INSTALLATION
The P36D is approved for a 40 ft. straight vertical, with rigid pipe vent
systems for Propane and Natural Gas, as per the diagram 1.
The shaded area in the diagram 1 shows all allowable combinations of straight
vertical and offset to vertical terminations with rigid pipe vent systems for
Propane and Natural Gas. Maximum two 45
Vent must be supported at offsets
Firestops are required at each floor level and whenever passing
through a wall.
Maintain clearances to combustibles.
26
o
elbows allowed.
Diagram 1
FPI P36D Zero Clearance Direct Vent Gas Fireplace