FPI P36D-NG Owners & Installation Manual page 37

P36d zero clearance direct vent gas fireplace
Table of Contents

Advertisement

02-54
02-51
5th Grate Tab
7) Place the bottom left front edge of Log
02-55 against the rear bracket on the burner
tray and rest the log on the cutout on
Log 02-53.
02-75
02-55
02-53
Rear Bracket
8) Place Log 02-52 between Logs 02-51 and
02-75 and on the indentation on Log 02-54.
The bottom right end sits behind the rear
grate tab.
02-52
02-51
02-54
Log indentation
FPI P36D Zero Clearance Direct Vent Gas Fireplace
02-54
Photo shows rear grate tab.
Log 02-51 was removed to show
the positioning of Log 02-52.
9) Sit Log 02-50 on the front left side of the
burner. Push the back of the log against the
2 front brackets with the notch on the
bottom of the log fitting into the first grate
tab.
Front Brackets
02-50
02-51
Notch
Cutouts
02-75
02-50
02-52
Rear
Grate
Tab
02-50
02-53
11) Test fire to ensure proper light off (make
02-55
12) Install flush glass and bay glass (if used) as
02-53
02-75
02-55
INSTALLATION
10) Place the embers on the front of the burner
tray in the places shown on the photos
below.
Place embers in these 3
locations on the burner tray.
02-51
Do not block the burner holes in
this area adjacent to the Log 02-54
sure flame flows smoothly from one end of
burner to the other). If there is any flame
hesitation, check that area for any blockage
of the burner ports.
per instructions in this manual.
02-54
02-51
02-54
37

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

P36d-lp

Table of Contents