Chapter 3 Operating Principles | PCI-DMC-A01 / PCI-DMC-B01
7) Start motion control (Using point to point motion control as an example)
Click on the "" or "" button to execute the following procedure:
rt = _DMC_01_start_sa_move(gDMCCardNo, NodeID, SlotID, Distance, StrVel,
MaxVel, acc, dec);
velocity cross-section
rt = _DMC_01_start_ta_move(gDMCCardNo, NodeID, SlotID, Distance, StrVel,
MaxVel, acc, dec);
velocity cross-section
rt = _DMC_01_start_sr_move(gDMCCardNo, NodeID, SlotID, Distance, StrVel,
MaxVel, acc, dec);
velocity cross-section
rt = _DMC_01_start_tr_move(gDMCCardNo, NodeID, SlotID, Distance, StrVel,
MaxVel, acc, dec);
velocity cross-section
8) Stop motion
Hit the "STOP" button to execute an emergency stop:
rt = _DMC_01_emg_stop (gDMCCardNo, NodeID, SlotID);
In this example, emergency stop is used to stop motion. This method quickly stops
motion by setting deceleration time to 0. For more information about the Stop Motion
function, refer to the later section on "Stop Motion Control API".
9) Exit procedure
Click on the "Exit" button to quit and exit the procedure.
"_DMC_01_reset_card" and "_DMC_01_close" must be executed to exit this
function. Please refer to Section 3.12 "Exit procedure" for the function operations.
3-86
// Motion displacement using absolute coordinates with S-curve
// Motion displacement using absolute coordinates with T-curve
// Motion displacement using relative coordinates with S-curve
// Motion displacement using relative coordinates with T-curve
Revised March, 2012