8.4 Error Correction
a)
1
2
b)
a)
Flap correctly aligned but fed at an angle.
Loosen screws 1 ( 2-off ).
Set bracket 2 with the swing cylinder and flap clamps
appropriately angled to the flap support.
ATTENTION !
Check the flap support, flap stop and aligning plate and
correct, if necessary.
b)
Flap correctly aligned but fed at an angle.
Loosen screws 1 ( 2-off ).
Set bracket 2 with the swing cylinder and flap clamps
appropriately angled to the flap support.
ATTENTION !
Check the flap support, flap stop and aligning plate and
correct, if necessary.
c)
Flap sewn in too low.
Loosen nut 3 and turn adjusting screw 4 in.
d)
Flap not sewn in low enough.
Loosen nut 3 and turn adjusting screw 4 out.
In case of wrong adjustments check switch S28.
c)
3
4
d)
49