Gripper needle rows
With dual piping, when the gripping folder lowers onto the placing
table, both gripper needle rows should enter at the same clearance
right and left of the central ridge 1.
Setting with the piping seat at the left
The cylinder 2 is in the forward position on the plate 5.
Loosen screws 3 and 4.
Set plate 5 with cylinder 2.
Tighten screws 3 and 4 again.
Setting with the piping seat at the right
The cylinder 2 is in the rear position on the plate 5.
Loosen lock nut 6.
Set stopper screw 7.
Tighten lock nut 6 again.