Error, Warning And Information Messages - Duerkopp Adler DACeco M-TYPE Operating Manua

Table of Contents

Advertisement

DACeco M-TYPE
8

Error, warning and information messages

The DAC
control unit contains three groups of messages that are divided as follows:
eco M-TY PE
Degree
Description
Error
Serious error
Turn off the control unit and correct the error.
Warning
Eliminate the condition that caused the warning and the control unit will continue to work normally.
Information Press OK
You can continue to work; only emergency running properties may be available.
The messages are visualised via LED2. The coding is displayed via LED2
flashing every 0.5 seconds. The flashing sequence is then interrupted for two seconds and
repeated.
Degree
Code
Warning
1
Information 2
Warning
3
Error
4
Error
5
Error
6
Error
7
Error
8
Error
9
Error
10
Error
11
Information 12
Error
13
Error
14
0791 100632 EN
Error or information description Remedial measures
Travel stop
Low voltage warning (1st threshold)
(mains voltage < 180V AC)
Pedal position is not in position 0
Pedal not connected
Sewing motor encoder plug (Sub-D,
9-pin) not connected.
Motor stalls
Sewing motor overload
Sewing motor error
Sewing motor plug (AMP) is not
connected.
Sewing motor insulation error
High voltage error, mains voltage
>290V for some time
EEprom communication error
No valid data on external EEprom
Low voltage failure (2nd threshold)
(mains voltage < 150V AC)
Sewing motor turning in the wrong
direction
Error, warning and information messages
- Check the tilt sensor on the machine
- Check mains voltage
- Stabilise mains voltage
- Use generator
- When switching on the control unit, take foot off
pedal
- Connect analogue pedal
- Insert the encoder lead into the control unit. Use the
correct interface.
- Eliminate sluggish movement in the sewing machine
- Eliminate sluggish movement in the sewing machine
- Check the connection and if necessary plug in.
- Test sewing motor phases (R= 2.8 Ohm, high-
resistance compared with PE)
- Replace sewing motor
- Replace control unit
- Check motor phase and PE for low-resistance
connection
- Replace sewing motor
- Check mains voltage, if rated voltage exceeded
permanently - stabilise or use generator
- Check the connection of the Mach ID
- Turn off the control unit, wait until LEDs are off,
restart
- Check the connection of the Mach ID
- Turn off the control unit, wait until LEDs are off,
restart
- Update software
- Check mains voltage
- Stabilise mains voltage
- Use generator
- Replace encoder
- Check that the motor plug is in the correct place and
change if necessary