4.6 Seat for the Gripping Folder
3
4
22
After the sideways swinging in to the center of the pocket opening the
clearance from the seating pin 4 to the forward-lying needles should
be 228 mm and the sideways clearance to the reference line 131 mm.
Caution Risk of Injury !
Turn the main switch off.
Set the gripping folder only with the main switch turned off.
Conduct setting work with the sewing machine running only while
exercising the greatest possible caution.
–
Pull out hose coupling 1.
–
Loosen screw 2 and remove the gripping folder.
The replacement of the gripping folder may only occur through the
loosening of the clamping screw 2 !
–
Turn the main switch on !
Activate the setting program " Checking the Gripping Folder
without Transport Clamp ". Press the F3 key.
The seat swings into the vertical.
131 mm
5
1
2
6