15.2.4 Removing and Attaching the Needle Bar Link

1
2
3
4
8
9
78
Caution Risk of Injury !
Turn the main switch off.
Remove or attach the needle bar link only with the main switch turned
off.
5
6
7
10
11
Removing the needle bar link
Loosen screws 8 and 11.
Remove cylinder 9 with swing lever 10.
Remove the head cover after loosening the mounting screws.
Loosen clamping screw 13 slightly.
Pull the knife drive lever 14 off of shaft 12 (Attention wedge!).
Loosen screws 19.
Remove guide plate 18.
Loosen screws 5.
Pull the mounting plate 7 with needle bar link 15 carefully from the
stopper pin 1.
Turning back and forth slightly makes pulling off easier.
If necessary, loosen an adjusting screw 2.
ATTENTION !
Do not loosen both adjusting screws 2.
With the adjusting screws 2 the link frame is set at the factory so that
the crosshead does not strike.
12
13
14
19
15
16
17
18