15.2.4 Removing and Attaching the Needle Bar Link
1
2
3
4
8
9
78
Caution Risk of Injury !
Turn the main switch off.
Remove or attach the needle bar link only with the main switch turned
off.
5
6
7
10
11
Removing the needle bar link
–
Loosen screws 8 and 11.
–
Remove cylinder 9 with swing lever 10.
–
Remove the head cover after loosening the mounting screws.
–
Loosen clamping screw 13 slightly.
–
Pull the knife drive lever 14 off of shaft 12 (Attention wedge!).
–
Loosen screws 19.
–
Remove guide plate 18.
–
Loosen screws 5.
–
Pull the mounting plate 7 with needle bar link 15 carefully from the
stopper pin 1.
Turning back and forth slightly makes pulling off easier.
–
If necessary, loosen an adjusting screw 2.
ATTENTION !
Do not loosen both adjusting screws 2.
With the adjusting screws 2 the link frame is set at the factory so that
the crosshead does not strike.
12
13
14
19
15
16
17
18