Service Menu Start Level; Requesting Service Menu Level 1; Insertion Distance Length, Photocell Correction For Beginning Of Seam - Duerkopp Adler 2211-5 Working Instructions

Short seam automat
Table of Contents

Advertisement

Beisler Automated Sewing Equipment
D.3
D.3.2 Service menu start level
The service functions of the service menu are requested
by direct access from the start level or from level 1. Ser-
vice functions support the working process during machine
production.
Functions on the start level
The function keys on the start level are assigned to the
symbols below them. These symbols cannot be changed;
they are always visible.
F1 Request service menu level 1
F2 Insertion distance length,
photocell correction for beginning of seam
F3 Change photocell correction for end of seam, seam
length and fixed seam end point
F5 Drive assistance transport to service position
F6 Actuate thread clamp manually
F7 Test cutters manually
F8 Reset insertion process

Requesting service menu level 1:

Direct access to the functions of the service menu on the
level 1.
Press
key.
Insertion distance length, photocell correction for
beginning of seam:
The settings control the beginning of the seam. They refer
to the currently selected seam and are in close relation
to the settings made using function F3 for the end of the
seam.
The menu offers two setting options:
The photocell response delay for the beginning of
the seam,
the setting of the insertion distance length at the
beginning of the seam
Photocell response delay:
To set the response delay of the photocell, the correspon-
ding function "Photocell for beginning of seam" must be
enabled (see Section D.3.9). The higher the input value,
the later the sewing process starts.
Programming
Short Seam Automat 2211-5 Working Instructions
Insertion distance length:
If the function "Photocell for beginning of seam" is disabled,
the beginning of the seam is controlled by a fixed inser-
tion distance (see Section D.3.9). The insertion distance
is the distance that the main clamp moves toward the
sewing head before the sewing head starts sewing.
The setting refers to a correction of the insertion length
for the beginning of the seam. The higher the input value,
the longer the insertion distance.
Enter value:
Press
key.
The cursor automatically marks the variable value.
To change this value gradually:
Press
or
Enter a completely new numeric value:
Enter numbers using numeric keypad.
Confirm input and exit menu:
Press
key.
NOTE - Checking settings!
The settings must be checked using a sewing piece; if re-
quired, they must be corrected.
- D 80 -