3.1 Stroke Movement of the Folder
6
7
8
9
10
Caution Risk of Injury !
Turn the main switch off.
Set the stroke movement of the folder only with the main switch turned
off.
With raised folder:
Between the lever 13 and the underside of the curve piece 12 there
must be a safety clearance of 3 mm.
–
Loosen nut 6.
–
Set the mounting of the cylinder 7 higher or lower accordingly.
–
Tighten nut 6.
With lowered folder:
The clearance between the folder sole and the cloth slider plate must
be 1 mm along the whole length.
–
Loosen nut 10.
–
Set the clearance between the underside of the folder sole and the
cloth slider plate by turning the piston rod of the cylinder 7.
–
If the roller touches on the lowest point of the curve path 8:
Loosen screws 11.
Set the curve piece 12 lower.
–
Loosen clamping screw 14.
–
Turn the folder slightly on axle 15.
There must be a uniform clearance between the folder sole and the
cloth slider plate along the whole length.
–
Tighten clamping screw 14 and nut 10.
–
In the lowest position of the folder set the curve piece 12 as
follows:
There must be a clearance of 0.5 mm between the roller and the
lowest point of the curve path 8.
–
Tighten screws 11.
11
12
13
14
15
16
11