PLC-HF15000L Expand Serial Command Functional Specifications
8.9.42 CF_FILCTL Command
Command
"CF_FILCTL_%1" [CR]
%1
"SKD" --------------- Schedule filter cleaning task
Details
Schedule filter cleaning
Acceptable
Response
Unacceptable
8.9.43 CF_FANSPEED Command
Command
"CF_FANSPEED_%1" [CR]
"MAX" ---------------------------- Select Maximum speed of Fan Control
%1
"NOR" ---------------------------- Select Normal speed of Fan Control
Switch Fan Control Speed. (Valid only when in the normal Power ON status.)
Details
The status set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable
8.9.44 CF_RCODE Command
Command
"CF_RCODE_%1" [CR]
"001" ------------------------------------ Select Code 1
"002" ------------------------------------ Select Code 2
"003" ------------------------------------ Select Code 3
"004" ------------------------------------ Select Code 4
"005" ------------------------------------ Select Code 5
%1
"006" ------------------------------------ Select Code 6
"007" ------------------------------------ Select Code 7
"008" ------------------------------------ Select Code 8
"UP" ----------- The same operation as pressing Up key or Left key
"DN" -----------The same operation as pressing Down key or Right key
Select Remote Control Code (Valid only when in the normal Power ON status)
Details
The status set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable
8.9.45 CF_RSENS Command
Command
"CF_RSENS_%1" [CR]
"ALL" ----------------------------------- Select top, front and back receiver of projector
"FRONTTOP" ------------------------ Select front and top receivers of projector
"BACKTOP" -------------------------- Select only back and top receivers of projector
"FRONTBACK" ---------------------- Select only front and back receivers of projector
%1
"FRONT" ------------------------------ Select only front receiver of projector
"TOP" ---------------------------------- Select only top receiver of projector
"BACK" ---------------------------- Select only back receiver of projector
"UP" ----------- The same operation as pressing Up key or Left key
"DN" -----------The same operation as pressing Down key or Right key
Select location of infrared remote receiver of remote control (Available only in the
normal Power ON status)
Details
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
55/105