PLC-WM5500/WM5500L Expand Serial Command Functional Specifications

8.10.19 CF_FILH Command

Command
"CF_FILH_%1" [CR]
%1
"RST" ---------------------- Reset Filter used time
Details
Reset used time for filter of projector
Acceptable
Response
Unacceptable

8.10.20 CF_FILTIMER Command

Command
"CF_FILTIMER_%1" [CR]
"0400" ---------------------- Set 400 hours
"0700" ---------------------- Set 700 hours
%1
"1000" ---------------------- Set 1000 hours
"OFF" ---------------------- Set Off(Do not warning display)
Details
Set time to display Filter cleaning / replacement warning on screen
Acceptable
Response
Unacceptable

8.10.21 CF_FILCTL Command

Command
"CF_FILCTL_%1" [CR]
%1
"ROLL" ---------------------- Execute operation of scroll of filter
Details
Execute operation of scroll of filter
Acceptable
Response
Unacceptable

8.10.22 CF_FILSCRL Command

Command
"CF_FILSCRL_%1" [CR]
%1
"RST" ---------------------- Reset Filter scroll counter
Details
Reset Filter scroll counter
Acceptable
Response
Unacceptable

8.10.23 CF_FANSPEED Command

Command
"CF_FANSPEED_%1" [CR]
"MAX" ------------------------------ Select maximum fan speed
%1
"NOR" ------------------------------ Select normal fan speed
Switch Fan Control Speed mode.(Available only in the normal Power ON status)
Details
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
46/88

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plc-wm5500Plc-wm5500/l

Table of Contents