PLC-WTC500L Expand Serial Command Functional Specifications
8.10.7 CF_FILCTL Command
Command
"CF_FILCTL_%1" [CR]
%1
"ROLL" ---------------------- Execute operation of scroll of filter
Details
Execute operation of scroll of filter
Acceptable
Response
Unacceptable
8.10.8 CF_POINTER Command
Command
"CF_POINTER_%1_%2"[CR]
"SPOTLIGHT" --------------- Select Spotlight
"ARROW" --------------------- Select Arrow
%1
"FINGER" --------------------- Select Finger
"LASER" ---------------------- Select Laser mark
"MAX" ------------------------- Spotlight Large
%2
"MID" -------------------------- Spotlight Medium
"MIN --------------------------- Spotlight Small
Select Pointer display. (Available only in the normal Power ON status)
Note1) %2 is valid only when "SPOTLIGHT" is specified in %1. When
Details
Note2) When "SPOTLIGHT" is specified in %1, %2 cannot be omitted.
Acceptable
Response
Unacceptable
8.10.9 CF_RCODE Command
Command
"CF_RCODE_%1" [CR]
"001" ------------------------------------ Select Code 1
"002" ------------------------------------ Select Code 2
"003" ------------------------------------ Select Code 3
"004" ------------------------------------ Select Code 4
"005" ------------------------------------ Select Code 5
%1
"006" ------------------------------------ Select Code 6
"007" ------------------------------------ Select Code 7
"008" ------------------------------------ Select Code 8
"UP" ---------- Switch forward (Code1→Code2→Code3 - - - →Code8→Code1)
"DN" --------- Switch backward (Code8→Code7→Code6 - - -→Code1→Code8)
Select Code of Remote Control (Available only in the normal Power ON status)
Details
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable
Acceptable
Unacceptable
"ARROW"/"FINGER"/"LASER" is specified in %1, the command should
be "CF_POINTER_%1" [CR].
"000"[CR]
"Error Code"[CR]
"000" [CR]
"Error Code" [CR]
37/75