PLC-HF15000L Expand Serial Command Functional Specifications

8.9.31 CF_CMTGG Command

Command
"CF_CMTGG_%1_%2" [CR]
"RED" ---------------------- Set value of Red
"GREEN" ----------------- Set value of Green
"BLUE" -------------------- Set value of Blue
%1
"WHITE" ------------------ Set value of White
"CYAN" -------------------- Set value of Cyan
"MAGENTA" ------------- Set value of Magenta
"YELLOW" --------------- Set value of Yellow
%2
"0000" – "1000" --------- Directly specify "g" value of color of %1
Set "g" value of Target of Color matching.
Details
(Available only in the normal Power ON status)
Acceptable
Response
Unacceptable

8.9.32 CF_CMAUTOTESTPAT Command

Command
"CF_CMAUTOTESTPAT_%1" [CR]
"ON" ---------------------- Set to On
%1
"OFF" -------------------- Set to Off
Set Auto test pattern of Color matching.
Details
(Available only in the normal Power ON status)
Acceptable
Response
Unacceptable

8.9.33 CF_CMRST Command

Command
"CF_CMRST_%1" [CR]
"CMRST" ---------------------- Reset setting of Color matching
%1
"ADCRST" -------------------- Reset setting of Advanced color matching
Details
Reset setting of Color matching.(Available only in the normal Power ON status)
Acceptable
Response
Unacceptable

8.9.34 CF_CMSTORE Command

Command
"CF_CMSTORE_%1" [CR]
"CMSTR" ---------------------- Store setting of Color matching
%1
"ADCSTR" -------------------- Store setting of Advanced color matching
Details
Store setting of Color matching.(Available only in the normal Power ON status)
Acceptable
Response
Unacceptable
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
52/105