PLC-HF15000L Expand Serial Command Functional Specifications
9.5.5 CR_CLAMP Command
Command
"CR_CLAMP" [CR]
Details
Get value of Clamp
Acceptable
Response
Unacceptable
9.5.6 CR_DDOTS Command
Command
"CR_DDOTS" [CR]
Details
Get value of Display Dots
Acceptable
Response
Unacceptable
9.5.7 CR_DLINE Command
Command
"CR_DLINE" [CR]
Details
Get value of Display Line
Acceptable
Response
Unacceptable
"000_%1" [CR]
%1
"0000" – " 4095"
"Error Code" [CR] -------------- When command is invalid in the
given condition (such as being selected input)
"?" [CR] --------- When unknown command is received
"000_%1" [CR]
"0256"-"nnnn"
%1
(nnnn = Total Dots – Position H)
"Error Code" [CR] -------------- When command is invalid in the
given condition (such as being selected input)
"?" [CR] --------- When unknown command is received
"000_%1" [CR]
"0100" – " nnnn"
%1
(nnnn = Total Line – Position V)
"Error Code" [CR] -------------- When command is invalid in the
given condition (such as being selected input)
"?" [CR] --------- When unknown command is received
70/105