PLC-HF15000L Expand Serial Command Functional Specifications

8.6 Input Control Command

8.6.1 CF_INPUT Command

Command
"CF_INPUT_%1" [CR]
"1" ---------------------------------- Select Input 1
"2" ---------------------------------- Select Input 2
"3" ---------------------------------- Select Input 3
%1
"4" ---------------------------------- Select Input 4
"UP"-------------------------------- Increment Input No. by 1
"DN"-------------------------------- Decrement Input No. by 1
Select Input (Only valid when it is in the normal Power ON status.)
Details
This command works the same way as "INPUT" button of the projector and
remote control.
Acceptable
Response
Unacceptable

8.6.2 CF_SOURCE Command

Command
"CF_SOURCE_%1" [CR]
"DIGITAL" ---------------- Select DVI Input
"ANALOG" --------------- Select Analog Input
"VIDEO" ------------------- Select Composite Video Input
"S-VIDEO" ---------------- Select S-Video input
"YPBPR" ------------------ Select Y, Pb/Cb, Pr/Cr Input
"YCBCR" ------------------ Select Y, Pb/Cb, Pr/Cr Input
"SDI1" --------------------- Select SDI 1 Input
"SDI2" --------------------- Select SDI 2 Input
"SCART" ------------------ Select SCART Input
%1
"HDCP" -------------------- Select HDCP Input
"HDMI" -------------------- Select HDMI Input
"LINKA-YCBCR" -------- Select LINK-A(YCBCR1) Input
"LINKB-YCBCR" -------- Select LINK-B(YCBCR1)Input
"DUAL-YCBCR1" --------- Select DUAL(YCBCR1)Input
"DUAL-YCBCR2" -------- Select DUAL(YCBCR2)Input
"DUAL-YCBCR3" -------- Select DUAL(YCBCR3)Input
"DUAL-YCBCR4" -------- Select DUAL(YCBCR4)Input
"DUAL-RGB1" -------- Select DUAL(RGB1)Input
"DUAL-RGB2" -------- Select DUAL(RGB2)Input
Select source of the currently selected Input. (Valid only when in the normal Power
ON status.)
Details
When selected Input does not meet the requirement for the specified %1, return
"101" [CR] and the command is not executed.
Acceptable
Response
Unacceptable
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]