Table 8: Power Input Module Cables and Wires Needed (continued)
Cable/Wire
Two 12-AWG wire leads
Two 12-AWG wire leads
ERX310 Router
One 10-AWG ground wire
Two 14-AWG wire leads (DC model
only)
Two 14-AWG wire leads (DC model
only)
One AC power cord (AC model only)
54
Cabling the Router for Power
From
Power input module Power A –48 VDC and
RTN leads
Power input module Power B –48 VDC and
RTN leads
Power input module ground terminal
Power input module Power A –48 VDC and
RTN leads
Power input module Power B –48 VDC and
RTN leads
Power input module AC power IEC receptacle
To
Appropriate leads on power source
No.1
Appropriate leads on power source
No.2
Termination ground
Appropriate leads on power source
No.1
Appropriate leads on power source
No.2
Appropriate AC power supply