Table 22: CT1/CE1 I/O Module RJ-48C Connector Pinout
Pin
1
2
3
4
5
6
7
8
For CE1 I/O modules with Telco connectors, the other ends of the cables are attached
to a balun panel that splits the signals from two Telco connectors to 20 pairs of BNC
connectors. We supply the Telco cables if you purchase a balun panel. Figure 57 on
page 135 shows the location of the Telco connectors on a CE1 I/O module and the
sequence of the pins in the connectors.
Figure 57: CE1 I/O Module with Telco Connectors
Figure 58 on page 136 shows the location of the 20 pairs of BNC connectors on a
balun panel. The cables from the CE1 I/O module are plugged into the two 50-pin
Telco connectors on the other side of the panel.
Signal
RX Ring
RX Tip
no connect
TX Ring
TX Tip
no connect
no connect
no connect