Property Description of Range Indicator Element
Property Description of Simple Indicator Element
For the user's convenience, simple indicator provides two states (ON/OFF) to let the user change the XOR
color of the base picture quickly. In the following left example figure, there are simple indicator elements on
the top of the pipe element. The simple indicator elements will change as shown as the right figure below.
Read Address
Text / Text Size
Font / Text Color
XOR Color
Revision Apr. 30th, 2007, 2007PDD23000002
Chapter 3 Element Function|ScrEdit Software User Manual
Variable
When this option is selected, there is Range n-1 for the user to
Limits
use. n represents the total state numbers and n-1 represents the
total range numbers. For example, if the read address is $0, and
the total state number of the element is 5, it indicates that there
is Range 0~4 for the user to use. Then, the lower limit value of
Range 0 is $1, the lower limit value of Range 1 is $2 and vise
versa.
Table 3.7.3 Property Description of Simple Indicator Element
The address can be internal memory or the controller address. (Please refer to
Table 3.2.2 Property Description of General Buttons.)
The user can set the text, text size, font and text color that provided by Windows®
to determine the text display on the element. (Please refer to Table 3.2.2 Property
Description of General Buttons.)
It is used to set XOR color of base picture.