Property Description of Pipe (1) / Pipe (2) Element
Low Region Color
High Region Color
Property Description of Pipe (3) Element
It is used to connect to water pipe element. Pipe (3) element is shown as the figure below:
Pipe Gauge
Property Description of Pipe (4) Element
It is used to connect to water pipe element. Pipe (4) element is shown as the figure below:
Revision Apr. 30th, 2007, 2007PDD23000002
Chapter 3 Element Function|ScrEdit Software User Manual
Minimum Value
It is used to set the minimum and maximum capacity of the pipe
element.
Maximum Value
Target
The user can decide if the target value displays or not by using
this option.
Value
Color
Ranges (Enable
Please refer to the description of Low & High Region Color.
range setting)
Variable
When the target value and low & high limit is a variable value,
target/range limits
the low limit address is Read Address+1, the high limit address
is Read Address+2 and the address of target value is Read
Address+3.
When the user has input the target value, low & high limit, and minimum & maximum
value, after pressing OK button, HMI will examine the value by referring to the
selected data length and data format.
This option is available and displayed in the property table only when the "Ranges"
option in the Detail Setup dialog box is selected. If the user sets the low limit value is
30 and the color of low limit region is in green, and then set the high limit value is 70
and the color of high limit region is in red, the pipe element will be shown as the
figures below:
When the value is 20
Use this option to set the pipe gauge. The selectable range is from 1 ~ 5. The setting
value 1 represents at least 13 pixels and the setting value 2 represents at least 26
pixels and vise versa.
When the value is 50
When the value is 80
3-25