Desk Mounting; Wall Mounting - H3C LS-3100-16TP-EI-H3-A-O Installation Manual

S3100 series ethernet switches
Table of Contents

Advertisement

Installation Manual
H3C S3100 Series Ethernet Switches
Note:
No guide rails are delivered with the device.
Ensure a clearance of 1U (44.45 mm, namely, 1.75 inches) between devices for the
purpose of heat dissipation.

3.1.2 Desk Mounting

When a 19-inch standard cabinet is not available, you can simply place the switch on a
clean desk. When doing so, you should ensure that:
The desk is stable and well grounded.
A clearance about 10 cm (3.9 in.) is reserved around the switch for heat
dissipation.
No heavy object is placed on the switch.
S3100-SI and S3100-TP-EI Series Ethernet Switches are designed with no fan.
Therefore, you should install them in a drafty environment, and keep at least a
vertical distance of 1.5 cm (0.6 in.) between devices if you need to stack switches
one upon another.

3.1.3 Wall Mounting

You can mount some models of S3100 Series Ethernet Switches on concrete walls or
wood walls. Table 3-4 lists the models that support wall mounting.
Table 3-4 Models supporting wall mounting
S3100-SI Ethernet
switches
S3100-EI Ethernet
switches
I. Introduction to screw and anchor kit
Figure 3-14 and Figure 3-15 show the recommended sizes (in mm) of screws and
anchor kits used for mounting:
Models supporting wall
Subseries
S3100-8T-SI
S3100-8C-SI
S3100-8TP-PWR-EI
S3100-16TP-PWR-EI
mounting
3-11
Chapter 3 Installation
Hole distance (mm)
169 mm (6.65 in.)
170 mm (6.69 in.)