Figure 3-13 Effect diagram of front mounting ear and guide rail installation
(1) Rear panel
No guide rails are delivered with the device.
Ensure a clearance of 1U (44.45 mm, namely, 1.75 inches) between devices for the purpose of
heat dissipation.

Desk Mounting

When a 19-inch standard cabinet is not available, you can simply place the switch on a clean desk.
When doing so, you should ensure that:
The desk is stable and well grounded.
A clearance about 10 cm (3.9 in.) is reserved around the switch for heat dissipation.
No heavy object is placed on the switch.
S3100-SI and S3100-TP-EI Series Ethernet Switches are designed with no fan. Therefore, you
should install them in a drafty environment, and keep at least a vertical distance of 1.5 cm (0.6 in.)
between devices if you need to stack switches one upon another.

Wall Mounting

You can mount some models of S3100 Series Ethernet Switches on concrete walls or wood walls.
3-4
lists the models that support wall mounting.
Table 3-4 Models supporting wall mounting
Subseries
S3100-SI Ethernet switches
S3100-EI Ethernet switches
(2) Guide rail
Models supporting wall mounting
S3100-8T-SI
S3100-8C-SI
S3100-8TP-PWR-EI
S3100-16TP-PWR-EI
3-10
Table
Hole distance (mm)
169 mm (6.65 in.)
170 mm (6.69 in.)