H3C LS-3100-16TP-EI-H3-A-O Installation Manual page 16

S3100 series ethernet switches
Table of Contents

Advertisement

Installation Manual
H3C S3100 Series Ethernet Switches
Note:
With a PoE card inserted in one expansion slot, an S3100-16C-SI Ethernet switch
will be a powered device (PD). In this case, the other expansion slot becomes
unavailable.
For details about LEDs on the front panel, refer to section 1.4.1 "Front Panel LEDs
of the S3100-SI/S3100-TP-PWR-EI/S3100-C-EPON-EI Series".
II. Rear panel
Figure 1-11 shows the rear panel of an S3100-16C-SI AC-powered Ethernet switch.
(1) AC power socket
Figure 1-11 Rear panel of an S3100-16C-SI AC-powered Ethernet switch
Figure 1-12 shows the rear panel of an S3100-16C-SI DC-powered Ethernet switch.
(1) DC input terminal block
Figure 1-12 Rear panel of an S3100-16C-SI DC-powered Ethernet switch
III. Power system
1)
S3100-16C-SI AC-powered Ethernet switches:
Rated voltage range: 100 VAC to 240 VAC, 50 Hz/60 Hz
Input voltage range: 90 VAC to 264 VAC, 47 Hz to 63 Hz
2)
S3100-16C-SI DC-powered Ethernet switches:
Rated voltage range: –48 VDC to –60 VDC
Input voltage range: –36 VDC to –72 VDC
IV. Cooling system
The S3100-16C-SI cools off naturally.
(2) Grounding screw
(2) Grounding screw
1-9
Chapter 1 Product Introduction