Auth Type
: None
Virtual IP
: 192.168.0.10
Master IP
: 192.168.0.101
VRRP Track Information:
Track Object
: 1
# Display information about track entry 1 on Switch B.
<SwitchB> display track 1
Track ID: 1
Status: Positive
Notification delay: Positive 0, Negative 0 (in seconds)
Reference object:
BFD session:
Packet type: Echo
Interface
: Vlan-interface2
Remote IP
: 192.168.0.101
Local IP
: 192.168.0.102
The above output shows that when the status of the track entry becomes Positive, Switch A is the
master and Switch B the backup.
# Enable VRRP state debugging and BFD event debugging on Switch B.
<SwitchB> terminal debugging
<SwitchB> terminal monitor
<SwitchB> debugging vrrp state
<SwitchB> debugging bfd event
# When Switch A fails, the following output information is displayed on Switch B.
*Dec
17
14:44:34:142
[Src:192.168.0.102,Dst:192.168.0.101,Vlan-interface2,Echo], instance:0, protocol:Track
*Dec 17 14:44:34:144 2008 SwitchB VRRP/7/DebugState: IPv4 Vlan-interface2 | Virtual Router
1 : Backup --> Master
# Display the detailed information of the VRRP group on Switch B.
<SwitchB> display vrrp verbose
IPv4 Standby Information:
Run Mode
: Standard
Run Method
: Virtual MAC
Total number of virtual routers : 1
Interface Vlan-interface2
VRID
: 1
Admin Status
: Up
Config Pri
: 100
Preempt Mode
: Yes
Auth Type
: None
Virtual IP
: 192.168.0.10
Virtual MAC
: 0000-5e00-0101
Master IP
: 192.168.0.102
VRRP Track Information:
Track Object
: 1
State : Positive
2008
SwitchB
reason: The status of the tracked object changed
Adver Timer
State
Running Pri
Delay Time
State : Negative
1-13
Switchover
BFD/7/EVENT:Send
: 1
: Master
: 100
: 0
Switchover
sess-down
Msg,