Omron ZS-L User Manual page 98

Zs-l series smart sensor
Hide thumbs Also See for ZS-L:
Table of Contents

Advertisement

Section 4
Linear Input/Output
■ About Digital Output
Of CompoWay I/F or non-procedural communication commands, if you want to use the
FlowDATA command to batch acquire data at high speed, set this setting to ON.
Note, however, that in measurement modes ([High] or [Custom]) having a short
measurement cycle, the measurement cycle changes according to the setting of this
digital output.
This setting automatically is set to ON when the graph display and logging functions of SmartMoni-
tor ZS are used.For example, if the mode is set to the high-speed mode at this time, the measure-
ment cycle becomes 1.5 times the measurement cycle.
When a measurement mode other than [High] or [Custom] is selected, this digital output setting
does not cause the measurement cycle to change.
FUN mode-[I/O SET]-[I/O SET]-[DIGITAL]
OFF
ON
ZS-L
4-8
User's Manual
Setting
Of the communication commands, the command (FlowDATA) for high-speed
batch acquisition of data is disabled.
When [High] is selected for the measurement mode, this setting automatically
turns OFF, and the measurement cycles becomes the fastest measurement
cycle.
Of the communication commands, the command (FlowDATA) for high-speed
batch acquisition of data is enabled.
Set this to ON to batch acquire data at high speed using communication com-
mands.
Note, however, that in measurement modes ([High] or [Custom]) having a
short measurement cycle, the measurement cycle becomes 1.5 times the
measurement cycle when this setting is set to ON.
Description

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zs-ld20tZs-ld40tZs-ld50Zs-ld80Zs-ld200