Section 2
Sensor Controller
Installing the Sensor Controller
■ Installing on the DIN track
The following describes how to attach the 35 mm wide DIN track by quick, easy opera-
tion.
●
Installation procedure
1.
Hook the connector end of the Sensor
Controller onto the DIN track.
2.
Push the Sensor Controller down onto the
DIN track until the hook on the I/O cable side
is locked.
Push down until you hear it snap into place.
Always hook the connector end of the Sensor Controller on the DIN track first. Hooking the I/O cable
end on the DIN track first may impair the mounting strength of the DIN track attachment.
●
Removal procedure
The following describes how to remove the Sensor Controller from the DIN track.
1.
Pull the hook on the I/O cable end of the
Sensor Controller downwards.
2.
Lift up the Sensor Controller from the I/O
cable end, and remove it from the DIN track.
ZS-L
2-4
User's Manual
DIN track (sold sepa-
rately)
PFP-100N (1m)
PFP-50N (0.5 m)
PFP-100N2 (1 m)
End plate (sold sepa-
rately)
PFP-M
Hook on connector
Hook on I/O cable
Hook on I/O cable