2.
Place the sensing object at the position (second
point) to perform scaling, and enter the desired
offset value (second point).
Press the LEFT key. The sub-display blinks.
3.
Press the SET key to apply the setting.
■ Manual Setting
Enter numerical values for scaling correction values.
FUN Mode-[OUTPUT]-[SCALING]-[ON]-[MANUAL]
Setting
SPAN
OFFSET
Setting Output Processing of Sensing Information
Sets the inclination of the sensor characters as a coefficient.
Range:-2.0 to 2.0
Measurement value
(mm)
2.0
-2.0
Adds/subtracts a fixed value to or from the measured value.
Range: -999.99 to 999.999
Measurement value
(mm)
INPUT POINT 2
DIG
VAL SET:OK
Description
Workpiece
displacement
Workpiece
displacement
Section 3
ZS-L
3-23
User's Manual