Section 3
Setting Output Processing of Sensing Information
SELF-DN
Set the hysteresis width based on the fluctuations in the measured values around the trigger
level.The hysteresis will be applied from the start of the sampling period and will prevent timing input
chattering.
ZS-L
3-26
User's Manual
Setting
The sampling period is the period that the measured value is smaller than the
specified self-trigger level. Hold measurement is possible without a sync input.
Measured
value
Self-trigger level
When SELF-DOWN is selected, the following items are subsequently dis-
played:
• TRG LEVEL
Sets the desired self-trigger level.
Range: -999.99 to 999.999
• TRG HYS
Sets the hysteresis width for the self-trigger.
Range: 0 to 999.999
Description
Sampling period
When a delay time is set, the timing when the measured value
becomes greater than the self-trigger level and the end of the sam-
pling period will not be synchronous.Sampling will end after the speci-
fied sampling period has elapsed.
Hysteresis width
(for self-trigger)
Action point
Return point