Setting Gain - Omron ZS-L User Manual

Zs-l series smart sensor
Hide thumbs Also See for ZS-L:
Table of Contents

Advertisement

Setting Gain

The ZS-L Series is equipped with a CMOS gain setup function so that even workpieces
having an extremely low amount of reflected light or workpieces having a large tilt can be
measured stably.
The measurement resolution sometimes drops when a large gain is set.
FUN Mode-[SENSING]-[GAIN]
Setting
1, 2, 3, 4, 5
Adjusts the internal gain of the CMOS image sensor.
(default value: 1)
1(gain small) → 5(gain large)
Setting the Sensing Conditions
Description
Section 3
ZS-L
3-17
User's Manual