Important installer information:
Observe the following warnings and cautions when installing the KP100L..
Significant property damage may possibly occur. Do not use the product in other
country than the designated country.
Significant property damage may possibly occur. Do not use the product with a
mistake of the country setting.
Functional lesion by injury and fire damage may possibly occur. Do not remove the
MC cap on the back of the product when you exchange the FAN Assembly.
Significant property damage may possibly occur. Execute the installation by a
person who has the qualification that authorized by the electric power company in
the region.
Electric shock and significant property damage may possibly occur. Do a correct
connection after confirming the polarity of the cable from the solar modules and
from the grid.
Fire by loose connection of AC terminal block may possibly occur. Confirm there is
no looseness in the screw of the AC terminal block during the maintenance.
When using the product by the state that tightening the screw of AC terminal block is
insufficient, fire by loose connection may possibly occur.
Insert the electric cable in the inner of AC terminal block by using special Rod
terminal and crimping pliers, and tighten the screw by tightening torque of 
1.2-1.5N•m.
Fire by loose connection of the MC connector may possibly occur. Use the
specialized tool for the crimping process of the MC connector. Insert the MC
connector surely until locking.
Injury by electric shock may possibly occur. Read this manual before installation,
operating and maintenance of the product, and follow the instructions carefully.
Injury or functional lesion by electric shock or burn injury may possibly occur. Do
not install the product in places that child's hand reaches.
Injury by electric shock may possibly occur. Do not open the cover foreside R during
energizing.
Significant injury by electric shock may possibly occur. Do not touch the terminal of
the MC connector. Do not remove the MC connector excluding the instruction of this
manual.
Significant injury by electric shock may possibly occur. Do not open the cover
foreside R and not touch the MC connector for three minutes after turning OFF the
breaker of the grid side and the solar module side.
Injury by electric shock may possibly occur. Connect the PE cable to the earth.