2 Design
Connecting the Communication Cable
Wiring for the communications cable to the KP100L as follow steps
(1) Remove the cap of communications cable clamp, and take the rubber bush out.
(2) Puncture only the necessary parts of the rubber bush taken out with a tool like gimlet, and pass wiring.
Use the cable and the wire in the table below.
Diameter of cable
Diameter of wire
Length in which the insulating coating of the
cable is peeled off and taken
Two spare rubber bush are bundled. Use bundled rubber bush when you make a mistake in the
punctured processing.
(3) Pass the communication cable through the hole of the product. Set the rubber bush in the main body of
the cable clamp, and tighten the cap lightly.
2 - 14
Cap
Rubber Bush
4.0mm
solid wire / 0.4-1.2 (AWG26-16)
7mm
Tighten the cap lightly
Grid Connect Photovoltaic Inverte KP100L-OD-USER'S MANUAL