Omron GRT1 - 11-2007 Operation Manual page 334

Slice i/o units
Table of Contents

Advertisement

Explicit Messages
Explicit
Read
message
/write
Offset
Write/
Compensates for scal-
Compensa-
Read
ing errors after scaling
tion after
with an offset value.
Scaling
Maximum
Read/
Reads the maximum
Value Read
Reset
value after power is
turned ON.
Minimum
Read/
Reads the minimum
Value Read
Reset
value after power is
turned ON.
Peak Value
Read The peak value is held
Read
and read.
Bottom
Read The bottom value is held
Value Read
and read.
Top Value
Read The top value is held
Read
and read.
Top Detec-
Read Reads the timing for
tion Timing
detecting top values.
Flag Read
Valley
Read The valley value is held
Value Read
and read.
Valley
Read Reads the timing for
Detection
detecting valley values.
Timing Flag
Read
HH Value
Write/
Sets the HH value.
Setting
Read
LL Value
Write/
Sets the LL value.
Setting
Read
H Value
Write/
Sets the H value.
Setting
Read
L Value
Write/
Sets the L value.
Setting
Read
Scaled
Read Reads analog input val-
Analog
ues for which have only
Input Value
been scaled.
Read
Rate of
Read Reads the rate of
Change
change for each sam-
Value Read
pling cycle.
Function
Service
code
Write:
10 hex
Read:
0E hex
Read:
0E hex
Reset:
35 hex
Read:
0E hex
Reset:
35 hex
0E hex
0E hex
0E hex
0E hex
0E hex
0E hex
Write:
10 hex
Read:
0E hex
Write:
10 hex
Read:
0E hex
Write:
10 hex
Read:
0E hex
Write:
10 hex
Read:
0E hex
0E hex
0E hex
Command
Class
Instance
Attribute ID
ID
ID
8F hex
01 to 40
71 hex
*1
hex
99 hex
8F hex
01 to 40
72 hex
*1
hex
9A hex
8F hex
01 to 40
73 hex
*1
hex
9B hex
8F hex
01 to 40
74 hex
*1
hex
9C hex
8F hex
01 to 40
75 hex
*1
hex
9D hex
8F hex
01 to 40
76 hex
*1
hex
9E hex
8F hex
01 to 40
77 hex
*1
hex
9F hex
8F hex
01 to 40
78 hex
*1
hex
A0 hex
8F hex
01 to 40
79 hex
*1
hex
A1 hex
8F hex
01 to 40
7C hex
*1
hex
A4 hex
8F hex
01 to 40
7D hex
*1
hex
A5 hex
8F hex
01 to 40
7E hex
*1
hex
A6 hex
8F hex
01 to 40
7F hex
*1
hex
A7 hex
8F hex
01 to 40
84 hex
*1
hex
AC hex
8F hex
01 to 40
85 hex
*1
hex
AD hex
Appendix A
Response
Data
*2
2 bytes
2 bytes
(−28000 to
(−28000 to
*3
28000)
28000)
2 bytes
*2
*3
*2
2 bytes
*3
2 bytes
*2
*3
*2
2 bytes
*3
*2
2 bytes
*3
*2
1 byte
*3
*2
2 bytes
*3
*2
1 byte
*3
*2
2 bytes
2 bytes
(−32768 to
(−32768 to
*3
32767)
32767)
*2
2 bytes
2 bytes
(−32768 to
(−32768 to
*3
32767)
32767)
*2
2 bytes
2 bytes
(−32768 to
(−32768 to
*3
32767)
32767)
*2
2 bytes
2 bytes
(−32768 to
(−32768 to
*3
32767)
32767)
*2
2 bytes
*3
*2
2 bytes
*3
313

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smartslice - 11-2007Smartslice grt1 series

Table of Contents